67
8-8-9. External output voltage controlON/OFF (:EXT:VOLT)
This command select the external output voltage control mode.
:EXT:VOLT <value>
Setting
<value> is as shown below:
0: Deactivates external output voltage control.
(for control from the panel or through communication)
1: Actives external output voltage control.
Application example :EXT:VOLT 1
Selects the exterenal output voltage control.
Query
:EXT:VOLT?
Inquires about the setting.
Response example
1
Indicates that external output voltage control is
working. “?” has the same function as <value>.
Remark
This command causes an error during sequence operation (RUN).
8-8-10. External output current control ON/OFF (:EXT:CURR)
This command selects the external output current control mode.
:EXT:CURR <value>
Setting
<value> is as shown below:
0: Deactivates external output current control.
(for control from the panel or through communication)
1: Activates external output current control.
Application example :EXT:CURR 1
Selects the external output current control.
Query
:EXT:CURR?
Inquires about the setting
Response example
1
Indicates that external output current control is
working. “?” has the same function as <value>.
Remark
This command causes an error during sequence operation (RUN).
8-8-11. OUTPUT switching (:EXT:OUTP)
This command selects output ON/OFF with external contacts.
:EXT:OUTP <value>
Setting
<value> is as shown below:
0: Control from the panel or through communication
1: Output On/Off with external contacts
Application example :EXT:OUTP 1
Selects output ON/OFF with external contacts.
Query
:EXT:OUTP?
Inquires about the setting.
Response example
1
Indicates that output On/Off with external
contacts is working. “?” has the same function
as <value>.
Remark
This command causes an error during sequence operation(RUN).