46
Fig. 5-15 Photo coupler current
5-8.
Activating output when turning on power
Using the output on/off function with the external contacts shown in Section
“5-7-4. Output ON/OFF with external contacts”
it is possible to turn on output
automatically as soon as power is input to the power supply unit.
The value stored automatically when the source voltage is cut off or the POWER
switch is shut off is output. Check the set value again before using this function.
5-9. Usage of sequence Function
Using the sequence function shown in Section
“5-5-4. Sequence function (04)”
Using the sequence function shown in Section
◆
See Section
“5-5-4. Sequence function (04)”
above for the procedures of
setting the sequence operation.
Download the application software exclusive for the sequence operation from
our homepage and create sequence programs in advance.
(1) Write sequence programs through the interface board.
(2) Activate the sequence function shown in Section
“5-5-4. Sequence function
(04)”.
(3) Execute sequence operation with the PRESET key(s).
Each PRESET key has two functions. Operations caused by pressing the
PRESET key and OUTPUT key re different in the normal operation and
sequence operation modes. These keys cause the following operations in
sequence operation.
Normal
operation
Sequence operation
PRESET 1
Starts or gives a pause to operation.
PRESET 2
Jumps to the step of the number one smaller than the step number.
PRESET 3
Jumps to the step of the number one larger than the step number.
OUTPUT