![Texas LMK04906B Скачать руководство пользователя страница 63](http://html.mh-extra.com/html/texas/lmk04906b/lmk04906b_operating-instructions-manual_1093846063.webp)
L M K 0 4 9 0 6 E V A L U A T I O N B O A R D O P E R A T I N G I N S T R U C T I O N S
SNAU126
63
3) Confirm PLL2 operation/locking
1)
Program LD_MUX = “PLL2_R/2”
2)
Confirm that LD pin output is half the expected phase detector frequency of PLL2.
i.
If not, examine PLL2_R programming.
ii.
If not, examine physical OSCin input.
3)
Program LD_MUX = “PLL2_N/2”
4)
Confirm that LD pin output is half the expected phase detector frequency of PLL2.
i.
If not, confirm OSCin_FREQ is programmed to OSCin frequency.
ii.
If not, examine PLL2_N programming.
Naturally, the output frequency of the above two items should be the same frequency.
5)
Program LD_MUX = “PLL2 DLD”
6)
Confirm the LD pin output is high.
7)
Program LD_MUX = “PLL1 & PLL2 DLD”
8)