Revised
-
December 2013
LMK04906 Family: Low-Noise Clock Jitter with Dual Loop PLLs
SNAU126A
7
Copyright © 2013, Texas Instruments Incorporated
Default CodeLoader Modes for Evaluation Boards
CodeLoader saves the state of the selected LMK04906B device when exiting the software. To
ensure a common starting point, the following modes listed in Table 3 may be restored by
clicking “Mode” and selecting the appropriate device configuration, as shown in Figure 2 in the
case of the LMK04906B device. Similar default modes are available for each LMK04906B
device in CodeLoader. Choose a mode with CLKin0 or CLKin2 for differential clock signal or
CLKin1 for a single ended signal.
Figure 2: Selecting a Default Mode for the LMK04906 Device
After restoring a default mode, press Ctrl+L to program the device. The default modes also
disable certain outputs, so make sure to enable the output under test to make measurements.
Table 3: Default CodeLoader Modes for LMK04906
Default CodeLoader Mode
Device Mode
CLKin
Frequency
OSCin
Frequency
122.88 MHz CLKin1, 122.88 MHz
VCXO
Dual PLL, Internal VCO
122.88
MHz
122.88
MHz
125 MHz CLKin1, 25 MHz VCXO
Dual PLL, Internal VCO
125 MHz
25 MHz
The next section outlines step-by-step procedures for using the evaluation board with the
LMK04906B. For boards with another part number, make sure to select the corresponding part