![Texas Instruments LMH0318 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/texas-instruments/lmh0318/lmh0318_programmers-manual_1094647007.webp)
Device Configuration
4.2
Common Register Commands
The followings macros specify register settings for common operations.
4.2.1
Enable Channel Control
In default mode, the shared registers are enabled. To change any channel specific parameter, input
selection, Eye Opening Monitor, Horizontal Eye Opening (HEO), or Vertical Eye Opening (VEO), channel
control must first be enabled as follows:
RAW
FF
04
07
//Select Channel Registers
Note: Share register 0xFF can be written/read all the time and does not require selection of share register
bank.
4.2.2
LMH0318 Reset Registers
The LMH0318 has two reset functions: CDR State Machine Reset and Register Reset.
4.2.2.1
LMH0318 CDR State Machine Reset
This operation should be done after changing any of the channel registers.
RAW
FF
04
07
//Select Channel Registers
RAW
0A
0C
0C
//Reset for the new settings to take place
RAW
0A
00
0C
//Release CDR Reset
4.2.2.2
LMH0318 Register Reset
Restore registers default settings:
RAW
FF
04
07
//Select Channel Registers
RAW
00
04
04
//Reset Channel Registers
RAW
FF
00
07
//Select shared registers
RAW
E2
01
0F
//Enable Clock Data Recovery (CDR) State Machine
RAR
E2
10
10
//Wait until bit 4 set
RAW
FF
04
07
//Select Channel Register
Note:
LMH0318 Register Initialization
must be done after issuing Register Reset
7
SNLU183 – September 2015
LMH0318 Programming Guide
Copyright © 2015, Texas Instruments Incorporated