Device Configuration
4
Device Configuration
The following sections provide guidance for programming the LMH0318 for certain common applications.
Throughout the rest of the document, macro examples are given to setup the device for different
configurations and settings.
4.1
Common Device Configuration
The LMH0318 supports SMPTE data rates. Once configured for SMPTE application, the LMH0318 can be
optioned to lock to a selection of data rates and report lock status. The following is an example of common
register settings for the LMH0318 initialization followed by possible settings to support SMPTE data rates.
Table 2. LMH0318 SMPTE Configuration
COMMAND
REGISTER
VALUE
MASK
//Comments
//Initialization sequence
RAW
FF
04
07
//Select Channel Registers
RAW
16
25
FF
//Enable Full Temperature Range
RAW
3E
00
80
//Initialize CDR State Machine Control
RAW
55
02
02
RAW
6A
00
FF
RAW
03
XX
FF
//Use the desired CTLE settings. See
to determine the
CTLE setting
RAW
0A
0C
0C
//Reset CDR
RAW
0A
00
0C
//Release CDR reset
//In default mode, the LMH0318 automatically locks to different SMPTE
and ST-2082/1 data rates
RAR
1
1
1
//Read LOS of IN0
//Assuming signal is present on IN0, enable IN0 to 75
Ω
OUT0 and power
RAW
31
1
3
down 50
Ω
OUT1
RAW
2F
00
C0
//Default SMPTE is enabled
RAW
0A
0C
0C
//Reset CDR
RAW
0A
00
0C
//Release CDR Reset
RAR
02
18
18
//If reg 0x02[4:3] = 11'b, CDR locked
RAW
0C
30
F0
//Setup register 0x0C to enable reg 0x02 to read the VCO divider settings
RAR
02
38
38
//0x02[5:3] Indicates lock rates
RAW
0C
00
F0
//Setup register 0x0C to enable reg 0x02 to read lock indication
6