Device Configuration
For test purpose only, the register sequence below determines the correct CTLE setting. Note, the
selected CTLE setting produced by the test mode works for all of the data rates; therefore, this test should
be done at the highest data rate. The CTLE compensates for the media not the data rate. Additionally, for
3 Gbps or lower, register 0x55 specifies the fixed CTLE setting when operating in CTLE test mode.
RAW
FF
04
07
//Select Channel Registers
RAW
2D
00
08
//Disable EQ over-ride
RAW
2C
40
40
//Enable VEO scaling
RAW
3E
80
80
//Enable HEO/VEO
RAW
6A
44
FF
RAW
31
20
60
//Enable CTLE Test Mode to optimize eye opening
RAW
0A
0C
0C
//Reset CDR for the new settings to take place
RAW
0A
00
0C
//Release CDR Reset
RAW
0C
00
F0
//Setup register 0x0C to read lock indication
RAW
02
18
18
//Wait until bits [4:3] = 11'b to indicate CDR locked
RAR
52
xx
FF
//Read EQ Boost setting and store in xx for normal mode of operation
RAW
03
xx
FF
//Save EQ Boost setting in reg 0x03
RAW
2D
08
08
//Enable the device to force EQ Setting from Reg 0x03
RAW
31
00
60
//Allow register 0x03 to control CTLE setting
RAW
3E
00
80
//Restore initialization settings
RAW
6A
00
FF
//Restore initialization settings
RAW
2C
00
40
//Disable VEO scale
11
SNLU183 – September 2015
LMH0318 Programming Guide
Copyright © 2015, Texas Instruments Incorporated