![Texas Instruments LMH0318 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/texas-instruments/lmh0318/lmh0318_programmers-manual_1094647016.webp)
Device Configuration
4.2.11.2.7
OUT1 Reclocked Data
RAW
FF
04
07
//Select Channel Registers
RAW
09
20
20
//Enable over-ride
RAW
1E
20
E0
//Locked: OUT1 Reclocked Data (valid only in locked condition)
4.2.11.2.8
OUT1 Full Rate Clock
The following sequence enables full rate or line recovered clock.
RAW
FF
04
07
//Select Channel Registers
RAW
09
20
20
//Enable over-ride
RAW
1E
40
E0
//OUT1 full rate clock
4.2.11.2.9
OUT1 10 MHz Clock
RAW
FF
04
07
//Select Channel Registers
RAW
09
20
20
//Enable over-ride
RAW
1E
A0
E0
//Enable 10 MHz on OUT1
4.2.12
Invert OUT1 Data Polarity
For ease of layout, there may be a need to invert the polarity of the OUT1 differential pair.
RAW
FF
04
07
//Select Channel Registers
RAW
1E
80
80
//Invert OUT1 Polarity
4.2.13
OUT0 and OUT1 Settings
The LMH0318 has programmable VOD (Voltage Output Differential), Pre-Emphasis (OUT0), PW (Pulse
Width OUT0 settings), De-Emphasis Settings, and individual power-down settings
16
LMH0318 Programming Guide
SNLU183 – September 2015
Copyright © 2015, Texas Instruments Incorporated