3. If you would like to place the scripts in the default ALP script folder, move them to the file location:
SPACER
C:\Program Files (x86)\Texas Instruments\Analog LaunchPAD 1.56.0010
SPACER
4. Verify there is successful local I2C communication that the script worked by going to the register tab,
selecting register 0x00 labeled I2C_DEVICE_ID, and reading the value as shown in
. If the value
is not 0x7A, then the correct profile has not been assigned to the correct USB2ANY ID. Consult
Figure 3-37. Reading I2C Device ID Within the Register Tab
5. Ensure that the devices are setup properly by checking that Pass Sts: displays Pass and Linked has a
frequency listed like shown in
. In addition, be sure that D3, labeled Lock, and D15 label Pass,
are illuminated on the DS90UB954EVM (or variant).
Figure 3-38. Verifying Pass and Lock for DS90UB954 (or variant) in ALP
6. Navigate back to the Scripting tab of the DS90UB954 (or variant) ALP profile and run the
953to954_patgen_YUV_1920x1080p-4Lanes-Working.py script to initialize a pattern generation from 953-
>954. The script may be found by clicking on the "Run PreDef Script" button. If the DS90UB954-Q1 (or
variant) is not using an I2C address of 0x7A (8-bit form), the script should be modified to use the correct I2C
address.
Troubleshooting
SNLU224C – SEPTEMBER 2017 – REVISED APRIL 2021
DS90UB95x-Q1 Serializer Evaluation Module
37
Copyright © 2021 Texas Instruments Incorporated