Figure 3-28. USB2ANY Without Enclosure
Figure 3-29. USB2ANY With Enclosure
9. When the
Update Firmware
button appears, the USB2ANY is ready to be updated with the new firmware.
Click the
Update Firmware
button to start the update process.
10. The message
Done!
will appear in the status area when the update completes successfully.
11. Click the
Close
button to return to the previous dialog. If you want to update the firmware on another
USB2ANY, go back to Step 2.
12. When finished updating firmware, click the
Done
button.
3.4.5 Identifying USB IDs and Corresponding Devices
If you connected both devices to the same machine and are having trouble identifying which device belongs to
which USB port, close the USB2ANY/Aardvark Setup, and unplug one of the USB cables from the computer.
ALP should automatically update which USB port is still in use. Take note of the remaining USB ID and note
whether the 954EVM or 953EVM is connected to the port. Reconnect the other USB cable and assign the
appropriate profile to each ID.
Alternatively, arbitrarily assign profiles to each of the USB IDs and open the device page that is assigned to the
953 by double clicking the name. Select the registers tab, click register 0x00 label I2C_DEVICE_ID, and read the
value, shown in
.
Troubleshooting
SNLU224C – SEPTEMBER 2017 – REVISED APRIL 2021
DS90UB95x-Q1 Serializer Evaluation Module
29
Copyright © 2021 Texas Instruments Incorporated