A-10 G
ETTING
S
TARTED WITH THE
CBL 2™ S
YSTEM
© 2000, 2003 T
EXAS
I
NSTRUMENTS
I
NCORPORATED
Error
Number
Error Cause
44
The order of the equation must be appropriate for the equation
type selected. For example, an equation order of 5 is not valid for
the mixed polynomial equation.
45
This error occurred because (1) equations were enabled when sending
Command 1, but the equation was never sent using Command 4, or
(2) GET statement was issued before sending Command 4.
49
Invalid units were selected for temperature when sending the
temperature for the sonic to use. Valid values are from 0 to 4.
52
A channel was selected that is not a valid channel. The channel
numbers are 1-3, 11, 21, and 31.
53
A data group was selected that is not valid. Valid values are from 0 to
5.
54
The beginning-of-data selector must be 0 (for start of data) or 1
through the number of points collected. A number outside of this
range will produce this error message.
55
The end-of-data selector must be 0 (for end of data) or 1 through
the number of points collected. A number outside of this range
will produce this error message. In addition, the end of the data
must not be before the beginning of the data.
59
Digital probe has failed to read or write as commanded by the
host.
61
An attempt has been made to collect more data than can be stored
in one data collection. This unit has 24K of memory dedicated to
data storage, allowing up to 12K samples to be stored. (for
example, 3072 samples per channel for 4 channels.) If more than
this is attempted, an error will result.
62
This error results when an attempt to return data is made and the
data has not been collected.
63
This error results when sending Command 6 and an invalid second
parameter.
76
This error results when sending Command 10 for a channel that
does not have data stored.
77
This error results when sending a Command 10 and selecting an
algorithm that has not been defined.
78
This error results when advanced algorithm is selected and the
input parameters for it are not correct.
80
This error indicates that the battery voltage is too low to safely
write to
FLASH
memory and an attempt has been made to write to
FLASH
memory. The batteries should be replaced immediately for
the unit to continue to perform properly.