DAC Output Wiring
7.2
The DAC is used to generate the ±10V analog output voltage. The operational amplifier is able to drive high
capacitance loads and protects the DAC.
Figure 7-2 : DAC Output Wiring
TTL I/O Interface
7.3
The 16 TTL I/O lines are realized with an input and output buffer with a 4.7k
pull up resistor for the tri-state
output function and an electronic protection array for ESD and overvoltage protection. See the following figure for
more information of electrical circuitry.
Figure 7-3 : TTL I/O Interface
While power-up and after reset all digital I/O lines are configured as inputs. Because of the pull-up resistor an
unused (open) digital I/O line will be read as ‘1’. A digital I/O line configured as input will appear as a high state to
the outside, as long it is not driven from the outside.
TPMC851 User Manual Issue 1.0.9
Page 63 of 65