PROBLEM
SOLUTION
When I light the grill it does not
immediately ignite.
-- Make sure the gas is turned ON.
-- Make sure there is a spark while trying to ignite the burner.
-- Push in and hold for approximately 5 seconds before turning
the knob.
-- Make sure your burner is clean.
The regulator makes noise
.
-- The vent hose on the regulator may be plugged, or the
regulator may be faulty.
-- Ensure the vent hole on the regulator is not obstructed. If
obstructed, clear the hole, and close the LP tank and gas
control valves. Wait ten minutes and re-start.
-- When turning on the LP tank valve, do not cover the vent hole
on the regulator.
-- Check the flames for proper performance; if the flames are
incorrect, replace the regulator.
The grill only heats to 200
°
F -
300
°
F.
-- Ensure the temperature gauge is functioning properly. Hold a
flame to the probe or compare the grill gauge to an oven
thermometer placed in the grill.
-- Ensure correct start procedure. Prior to lighting the grill, the gas
control knobs should be OFF. The propane bottle should be
OFF. If not, wait 15 minutes. Turn the tank all completely ON.
Turn the left burner to ignite, wait 5 seconds, and ignite.
Repeat for additional burners.
-- Check all gas connections for leaks with a soap-water bubble
test. If leaks are found, replace the part or tighten the fitting.