Operation and Storage Manual of Panel Heater
Visualization on Display in “Wi-fi” settings
:
Work mode of display:
When pressed - backlight intensity - 100%; after 5s – OFF
Sound option
If the customer wants to deactivate sound function - push the “Mode”
button
for 3 sec and select “Sound” mode
by pushing any of the
buttons:
or
and confirm with “Mode” button
. To turn off the
sound, choose degree 0 through the buttons
or
. Confirm with
“Mode” button
.
• If the customer wants to activate sound function – push the “Mode”
button
for 3 sec and select “Sound” mode
by pushing any
of the buttons:
or
. Confirm with “Mode” button
. The
user can select 5 degrees of sound volume via the buttons
or
. Confirm with “Mode” button
. In this case, the sound function is
turned on at the level you selected.
Visualization on Display in “Sound” settings
:
Device info
If the customer wants to view “Device info” - by pushing the “Mode” button
for 3 sec and select “Device info” by pushing any of the buttons:
or
. Confirm with “Mode” button
.
Visualization on Display in “Device info”
- ID
- MAC address
- Firmware version
Quick menu
Push the “Mode” button
to start quick already configured program. Select
by pushing any of the buttons:
or
and confirm with “Mode” button
. The program going to start to work.
Content function:
- Comfort
- Eco
- Sleep
- Delay start
- Weekly schedule
Exit from the any mode – with single pushing of ON/OFF button
.
Errors mode:
If the display shows “t1” or “t2“, this means that the self-diagnostic system has
found a problem with the temperature sensor. “t1” indicates a disconnected
cable at the sensor, while “t2” indicates short circuit at the sensor. In this case
the electric convector will be automatically switched off and it can be switched
on again only after the problem has been fixed. The problem has to be handled
by a qualified specialist.
DISCONNECTION FROM THE POWER SUPPLY:
If the electric convector is disconnected from the mains, this will not affect
the set temperature and the mode of operation which has been active prior
to its disconnection. If for example the convector has been in “Heating” mode,
after it has been disconnected and reconnected to the mains, it will continue
operating in the same mode with the same set temperature.
The principle of operation of the electric convector with energy-independent
memory is to store the settings for 120 minutes guaranteed, and up to 180
minutes not guaranteed.
If the time is more than 120 min the appliance going to Stand by mode.
PROTECTION
• The appliance is equipped with a safety thermo turn-off device, which
automatically turns the heater off in cases of extreme temperature of the
panel heater /i.e. overheating of the appliance/.
• The safety thermo turn-off device will automatically restore the heater
operation when the temperature of the appliance falls below the
permissible ultimate values.
CLEANING
• It is compulsory first to turn off the appliance through its power
switch and to disconnect it from the power socket. Before starting the
cleaning session you should wait until the panel heater cools down in a
disconnected state.
• Clean the heater body with damp cloth, vacuum cleaner or a brush.
• Never immerse the appliance into water – there is danger for your life
from electric shock!
• Never use gasoline, thinner or hard abrasive products to clean the
appliance, because they will damage the appliance coating.
STORAGE
• Before putting the panel heater away let it cool down after you have
disconnected it from the power socket
• Use the appliance original packing to store it, if the panel heater will not
be in use for a long period of time. By storing the product in its original
packing you protect it from excessive dirt and dust accumulation.
• Never put a hot panel heater in its packing!
• It is necessary the product to be stored at a dry and dark place, protected
from direct sun light.
•
It is explicitly forbidden to store the panel heater in damp and wet premises.
MAINTENANCE OPERATIONS OF THE APPLIANCE
• In case of appliance malfunction, please contact the authorized service
center closest to your location. /service centers are indicated in appliance
warranty documents/.
•
Important
: In case of a claim and/or violation of your consumer rights,
please contact the supplier of this appliance at the indicated locations or
via the Internet page of the company: www.tesy.com
•
DIMENSIONS OF HEATED VOLUME AND HEATED AREA OF A ROOM /
APPLIANCE MODELS
Model
Heated volume
Heated area
CN 06 060 EA [CLOUD] [AS] W
- 600W
10* - 23 m
3
4* - 9 m
2
CN 06 100 EA [CLOUD] [AS] W
- 1000W 24* - 33 m
3
10* - 13 m
2
CN 06 140 EA [CLOUD] [AS] W
- 1400W 34* - 45 m
3
14* - 18 m
2
CN 06 200 EA [CLOUD] [AS] W
- 2000W 46* - 65 m
3
19* - 26 m
2
* Minimum guaranteed heated volume (area) for heating at an average capacity of heat transmission
factor λ=0.5 W/(m
2
K) for a heated room. Higher values of heated volume (area) can be achieved at an
average value of λ=0.35 W/ (m
2
K). Standard height of heated rooms – 2.5 meters.