background image

Safety Precautions 

 

 

This high voltage probe must only be used by personnel who are trained, experienced, or otherwise 
qualified to recognize hazardous situations and who are trained in the safety precautions that are 
necessary to avoid possible injury when using such a device. 

 

Do not work alone when working with high voltage circuits 

 

For your own safety, inspect the probes for cracks and frayed or broken leads before each use. If 
defects are noted, DO NOT use the probe. 

 

Hands, shoes, floor and work bench must be dry. Avoid making measurements under humid, damp 
or other environmental conditions that might effect the safety of the measurement situation. 

 

It is advisable to turn the high voltage source off before connecting or disconnecting the probe. 

 

The probe body should be kept clean and free of any conductive contamination. Refer to the section 
on cleaning. 

 

Operation 

 

Connect the probe to the BNC input of the oscilloscope.

 

Select the desired volts/division range. (If you can set probe attenuation on the oscilloscope, set it to 
1000:1)

 

Whenever possible, turn the high voltage source off before making any connections.

  

Connect the divider probe ground lead (alligator clip) to a good earth ground or reliable chassis 
ground.

 

Before turning on the high voltage source, make sure that no part of the person holding the probe is 
touching the device under test. Once this is certain, turn on the high voltage source.

 

Measure the voltage under test and observe the waveform on the oscilloscope. Remember the 
actual voltage is 1000 times greater than the oscilloscope waveform if the probe attenuation has not 
been set to 1000:1.

 

Turn off the high voltage source

 

Disconnect the High Voltage Probe from the high voltage source BEFORE disconnecting the ground 
clip lead.

 

 

 

Do not attempt to take measurements from sources where the chassis or return lead is not grounded 

 

The ground lead is critical to the safe operation of the probe. Failure to make this connection when 
making high voltage measurements may result in personal injury or damage to the probe or 
oscilloscope. This connection must always be made BEFORE the probe tip comes in contact with 
the high voltage and must not be removed until the probe tip has been removed from the high 
voltage source. 

 

Do not connect the ground clip lead to the high voltage source for any reason. 

 

Do not make any floating measurements with the Testec High Voltage probe. 

 

Cleaning 

 

 

Clean only the exterior probe body and cables. Use a soft cotton cloth lightly moistened with a mild 
solution of detergent and water. Do not allow any portion of the probe to be submerged at any time. 

 

Dry the probe thoroughly before attempting to make voltage measurements. 

 

Do not subject the probe to solvents or solvent fumes as these can cause deterioration of the probe 
body and cables. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Warning 
 
 
 
 
 
 
 
 

Содержание TT-HVP 15HF

Страница 1: ...em Eingangswiderstand von 1 M 1 und einer nominalen Eingangskapazit t zwischen 15 und 30 pF Diese Modell ist ein 1000 1 Teiler der die Spannungsmessleistung auf 15 kV DC bzw 10 kV RMS AC 30 kV Spitzen...

Страница 2: ...rt Verwenden Sie einen auf ungef hr 100 Hz Ausgang eingestellten Rechteckgenerator Gehen Sie zur Frequenzkompensation folgenderma en vor 1 Schlie en Sie den Tastkopf an das Oszilloskop an 2 Verbinden...

Страница 3: ...gsquelle sicher dass die Person die den Tastkopf h lt mit keinem K rperteil die zu testende Vorrichtung ber hrt Ist dies gew hrleistet schalten Sie die Hochspannungsquelle an 6 Nehmen Sie die Spannung...

Страница 4: ...Testec Elektronik GmbH Westerbachstr 58 D 60489 Frankfurt Telefon 49 0 69 94 333 5 0 Fax 49 0 69 94 333 5 55 E Mail info testec de http www testec de...

Страница 5: ...t capacitance between 15 and 30 pF The 1000 1 divider extends the voltage measurement capability to 15 kV dc or 10 kV rms ac 30 kV peak Specifications Maximum Input Voltage Temperature Coefficient DC...

Страница 6: ...ed with the probe Use a square wave generator set for approximately 100 Hz output Proceed with the following steps for frequency compensation 1 Connect the probe to the oscilloscope 2 Connect probe ti...

Страница 7: ...n holding the probe is touching the device under test Once this is certain turn on the high voltage source 6 Measure the voltage under test and observe the waveform on the oscilloscope Remember the ac...

Страница 8: ...Testec Elektronik GmbH Westerbachstr 58 D 60489 Frankfurt Telefon 49 0 69 94 333 5 0 Fax 49 0 69 94 333 5 55 E Mail info testec de http www testec de...

Страница 9: ...et une capacit d entr e nominale entre 15 et 30 pF Ce mod le est un diviseur 1000 1 qui tend la puissance de mesure de la tension 15 kV DC ou 10 kV RMS AC 30 kV tension de cr te Sp cifications Tensio...

Страница 10: ...un g n rateur rectangle r gl sur une sortie d environ 100 Hz Proc der de la mani re suivante pour effectuer la compensation de fr quence 1 Brancher la sonde sur l oscilloscope 2 Raccorder le bec de m...

Страница 11: ...rce haute tension s assurer que la personne qui tient la sonde ne rentre pas en contact aucune partie de son corps avec le dispositif tester Si cette condition est assur e brancher la source haute ten...

Страница 12: ...Testec Elektronik GmbH Westerbachstr 58 D 60489 Frankfurt Telefon 49 0 69 94 333 5 0 Fax 49 0 69 94 333 5 55 E Mail info testec de http www testec de...

Страница 13: ...nza di ingresso di 1 M 1 e una capacit di ingresso nominale compresa tra 15 e 30 pF Questo modello un divisore 1000 1 che estende la capacit di misura della tensione a 15 kV DC o 10 kV RMS AC tensione...

Страница 14: ...ll oscilloscopio con essa utilizzato Usare un generatore di impulsi rettangolari regolato su circa 100 Hz in uscita Per la compensazione di frequenza procedere nel modo seguente 1 Collegare la testa d...

Страница 15: ...ensione assicurarsi che la persona che tiene la testa di scansione non sia a contatto con nessuna parte del corpo con il dispositivo da controllare Assicurato questo inserire la sorgente di alta tensi...

Страница 16: ...Testec Elektronik GmbH Westerbachstr 58 D 60489 Frankfurt Telefon 49 0 69 94 333 5 0 Fax 49 0 69 94 333 5 55 E Mail info testec de http www testec de...

Отзывы: