RSWA User’s Guide
5.3 C-Scan Area
is area shows the image that is created from the collected measurement data. e green
areas have fusion and the red areas do not have fusion.
Figure 5.3
C-scan area
Dotted Circle –
Shows the automatic estimation of weld nugget location and diameter. If
the estimation is off it can be manually adjusted by clicking the hand icon. Dragging the
edge of the circle will resize it and dragging the interior of the circle will reposition it.
e dots turn blue when in manual mode. Clicking the hand a second time will undo
any manual modifications.
Small Background Squares –
Represent the transducer’s elements. e currently selected
elements waveform will be shown in A-scan area (see Section 5.4).
Spinning Wheel –
Shows minimum/nominal size of the weld.
Hand Button –
Switches to manual circle sizing and back.