background image

 

• Safari starting from version 12.1 

• Firefox starting from version 53 

• Edge starting from version 80 

Internet Explorer is not supported. 

4.2 Requirements for video records storage 

• SSD or USB memory stick is recommended. HDD usage is not recommended; 

• If the USB drive consumes more than 2.5 W (500 mA) of power, it must be powered through an external power 

source; 

• USB Memory stick must be capable of writing to at least 120 Mbit/s; 

• While writing DO NOT detach the drive from the device. This can corrupt files or the drive itself; 

• Use “unmount” (see section 5.6.1) function before removing the drive; 

• It is recommended to use the disk with NTFS or exFAT file system. In case of FAT32, the file size will be limited 

to 4 GB, and some of TV programs may not fit in the file. 

• A USB hub can be used to connect multiple USB devices. However, only one disk partition will be active for 

recordings storage. 

4.3 Initial configuration 

To access the streamer WEB configuration interface, wait until the 

green

 or 

red

 status indication light appears 

on the device front panel.

 

4.3.1 Accessing the device when connected to the home router  

The DHCP client is enabled on the device by default. This means that the IP address will be assigned to the 

device automatically by the network router. The device also has the mDNS protocol enabled so you can access 

the device by entering this URL in your WEB browser address bar: 

http://iptv.local 

The login window should appear after a short period of time. 

If you cannot access the login window please read “troubleshooting instruction manual” for possible 

connection problems solving. 

NOTE: mDNS is supported on Windows and MAC operating systems only. If you are using other OS, connect 

the device directly to the personal computer as described in the section 4.3.2. 

4.3.2 Accessing the device when connected directly to the personal computer 

When device is connected directly to the personal computer or if there is no DHCP server in the network, the 

default IP address of streamer is: 

192.168.1.10 

Ensure that subnet 192.168.1.0 is accessible from your computer. If you are not sure, please read 

“troubleshooting instruction manual” for more information. Enter this IP address in your WEB browser address 

bar and the login windows should appear in a short period of time. 

4.3.3 Login access window 

Enter the following default login access parameters after login window shows up: 

Username: 

admin

 

Password: 

admin

 

4.3.4 Initial country selection 

When you connect to the device for the first time, you will be prompted to select the language, country, and 

region where the device is located (see Figure 2). Incorrect country selection can affect time zone and other 

important device settings. Make sure the setting is set correctly. 

Содержание MHI512R

Страница 1: ...power supply of the streamer into the mains until all the cables have been connected correctly The streamer shall not be exposed to dripping or splashing water Avoid placing streamer next to central heating components near highly combustible materials and in areas of high humidity If the streamer has been kept in cold conditions for a long time keep it in a warm room no less than 2 hours before us...

Страница 2: ...R receiver sensor for virtual remote controller learning function 4 Installation instructions Read the safety instructions first Connect the Set Top Box HDMI video output to the device HDMI IN connector using HDMI cable If required connect device HDMI OUT video output to the TV HDMI video input by using HDMI cable Connect IR blaster to the device IR socket and point its head to the STB front panel...

Страница 3: ...The device also has the mDNS protocol enabled so you can access the device by entering this URL in your WEB browser address bar http iptv local The login window should appear after a short period of time If you cannot access the login window please read troubleshooting instruction manual for possible connection problems solving NOTE mDNS is supported on Windows and MAC operating systems only If yo...

Страница 4: ... red circle indicates that there is a problem with device and user attention is required Click on this icon to see the detailed diagnostics errors description window Download and read the latest device user manual by clicking on this icon Currently logged in user name is shown at the top right WEB configuration window side You can log out anytime from the WEB configuration window by pressing on th...

Страница 5: ...qual to the video input source resolution Video bitrate higher video bitrates gives you higher video quality However higher network bandwidth is required as well If device is located far from your physical location and network bandwidth is limited you may use lower video bitrate value such as 1000 kbps If you are using device on your local network and network bandwidth is not limited then you can ...

Страница 6: ...uded sticky mounting pad to mount and direct the IR blaster head to the Set Top Box front panel Figure 7 Direct the IR blaster head to the STB front panel 5 3 3 Removing all programmed buttons Select the action Reset keys to remove all programmed virtual buttons Click Reset and then OK to confirm the action 5 4 Set Top Box This configuration window allows automating processes such as automatic STB...

Страница 7: ...file Edit selected channel preset Remove selected channel preset Add new channel preset 5 4 3 Adding new preset Click on the icon and Add or edit channel configuration window will appear see figure 10 Figure 10 New channel preset configuration window Type in the channel Title Channel number and select remote controller buttons sequence from the dropdown list Virtual remote controller buttons must ...

Страница 8: ... able to use the playlist file and watch video After filling the URL key with a secret key phrase you must download the playlist file again and import downloaded file to the video player that you are using Leave this field blank if playlist security feature is not required Channel title if no channels are added into the streamer STB channels list table then only one default channel will be availab...

Страница 9: ...dress field must specify the full path to the drive Domain name is not supported in this field The address must begin with characters followed by the IP address If the drive requires username and password add them to the appropriate fields Otherwise leave these fields blank Make sure the connection to the network drive is stable throughout the connection Otherwise the recording process of the unit...

Страница 10: ...t check box will use a home router s DHCP server to automatically assign the IP settings IP address subnet mask gateway DNS server Leave check box unchecked if you want to set IP address Subnet mask Gateway DNS server manually Application will restart if IP address is changed WEB port is the port number of the control interface Default value is 80 DO NOT change it unless you really need having WEB...

Страница 11: ...lue should be equal to local streaming port value Otherwise Terra TV app or third party video players may not work correctly WEB port is the device control port number Enable this port to access the device WEB interface remotely Also enable this port to use Terra TV Android app remotely The Debug port can only be used if you have a problem and ask the Support for help to resolve it Otherwise keep ...

Страница 12: ...ddress Otherwise secure connection link will be displayed on the login page for simpler access NOTE If the redirection fails for any reason certificate expired incorrect router forwarding etc forced redirection can be disabled by adding a question mark after the URL For example http 192 168 1 10 5 8 System menu This menu provides additional system parameters related to the system management Depend...

Страница 13: ...te a new user A new pop up window as shown in Figure 26 will appear The Role parameter is a type of user access rights You can select Administrator User or Guest Figure 26 Entering a new user Admin user has no restrictions User is almost the same as Admin but user management is disabled Guest has read only access which means no device settings can be changed A user with administrator access rights...

Страница 14: ...sion The table see example Figure 28 with a list of the latest firmware releases will appear on the screen Figure 28 Firmware releases history To download the firmware from the server to your computer click on the download icon indicated by an arrow in the picture Note Current software version will be shown if the device already has this firmware version Various notes will be provided here for eac...

Страница 15: ... Language country submenu a pop up window as shown in Figure 2 will appear prompting you to select the language country and region where your device is located Incorrect country selection can affect the time zone and other important settings Make sure this setting is set correctly DST means that the time zone contains winter and summer time which will be selected automatically according to the cou...

Страница 16: ...es not exists WEB interface port will reset to default value 80 A full reboot of the device will then be performed Restore defaults Pressing the button for longer than 7 seconds will activate the Restore defaults function Red blinking LED will indicate an activated command After releasing the button all device parameters will be restored to their default values and application will be restarted IP...

Страница 17: ...er programmable buttons 32 Control port IEE802 3 10 100 Base T Current consumption without external load 12 1 V 350 mA MHI512R Current consumption with max external load 12 1 V 800 mA MHI512R Supply voltage limit values power consumption 100 240 V 50 60 Hz 11 W max MHI512RP Operating temperature 0º C 45º C Dimensions Weight packed 112x35x124 mm 0 24 kg MHI512R 112x35x124 mm 0 34 kg MHI512RP Packag...

Отзывы: