The sensors shall be installed at a distance from the stove to avoid false actuation. During the assembly and
service maintenance of smoke sensors it is necessary to follow the instruction provided by the manufacturer for
their assembly and location.
It is recommended to install the sensors at the level of «table» (but not close to the ceiling) to avoid false
actuation. Make sure that sensors actuate for the presence of carbon monoxide. In case of fire alarm (sensor
actuation):
n
Pay attention to the signs of poisoning with carbon monoxide: headache, sickness, sleepiness.
n
Increase the intensity of ventilation (open windows, doors)
n
Make sure that door and ash-drawer at the stove are shut tight
n
Check – if there is smoke from the stove (through the air dampers)
n
Check the connecting pipe and stove pipe for the presence of blowing, smoke obstacle, and back-draught.
n
Check carbon monoxide sensors for false actuation.
It is strictly prohibited to change the system of air supply into the fire chamber if you want to increase the
flame. The changes of air supply into the fire chamber differing from the designed one will create dangerous
conditions for the stove use.
ATTENTION! Place power lead and electrical equipment in the safety area described in the manual.
During the economical combustion takes place the intensive generation of tar and other organic fumes that
are mixing with exhausted steam and generated creosote. Creosote fumes condensate at relatively cold surfaces of
the stove pipe and may be accumulated there. And if afterwards they ignite this creates extreme temperatures in the
chimney stack and may lead to ignition of materials surrounding the pipe and cause fire.
ATTENTION! Provided the creosote ignition in the stove pipe shut all air dampers of the stove, leave the
room and call the firemen.
ATTENTION!
The heating stove is a fire-hazard source
.
Open and close the door only by the handle. Raked out ashes and drosses from the combustor shall be
extinguished with water and shall be located in a special fireproof place.
ATTENTION! Don't perform a mechanical cleaning and servicing of the stove till its full cooling.
Maintenance work of the stove and the chimney shall be regularly done for most efficient and safety operation
of the stove.
Sweep chimneys and stoves before the beginning of heating season and also during it in accordance with the
«Rules of fireproof routine in the Russian Federation» at least:
n
Once in three months for stoves;
n
Once in two months for continuous furnaces and fire-places;
n
Once in month for ovens and other stoves of continuous (long-term) heat.
It is necessary to use the stove, out of bounds of the Russian Federation, in accordance with technical standards
of a country, where the stove would be exploited.
Involvement of experts for checking and sweeping a chimney is preferable.
ATTENTION! The company «Termofor» doesn't have responsibility for consequences of unqualified work
to sweeping and checking of the chimney or the stove.
The chimney can be cleaned both mechanically (with special devices, such as bristle brushes, brushes, loads,
scrapers) and chemically (with the special chemical purifier «log-sweep»). A bristle brush would be selected
8. SERVICING