TT22H
TT22HS
Nominal heat output
7,5 kW
7,5 kW
Height: 1093mm
1093mm
Width:
756mm 756mm
Depth:
476mm 476mm
Weight:
ca. 190kg
ca. 250kg
Average values for testing of TT22 models:
Exhaust gas temperature
259 °C
Exhaust gas mass flow
6,2 g/s
Efficiency
82%
Nominal Heat output
7,5 kW
Flue draught
12 Pa
SUPPLEMENTARY INSTRUCKTIONS UK
READ THE INSTRUCTION BOOKLET AND THESE SUPPLEMEN-
TARY INSTRUCTIONS CAREFULLY BEFORE INSTALLATION
These instructions together with those in the instruction booklet co-
ver the basic principles to ensure the satisfactory installation of the
stove, although detail may need slight modification to suit particular
local site conditions.
In all cases the installation must comply with current Building Regu-
lations, Local Authority Byelaws and other specifications or regulati
-
ons as they affect the installation of the stove.
It should be noted that the Building Regulations requirements may
be met by adopting the relevant recommendations given in British
Standards BS 8303, BS EN 15287-1:2007 as an alternative means
to achieve an equivalent level of performance to that obtained fol-
lowing the guidance given in Approved Document J.
Please note that it is a legal requirement under England and Wales
Building Regulations that the installation of the stove is either car-
ried out under Local Authority Building Control approval or is instal-
led by a Competent Person registered with a Government approved
Competent Persons Scheme. HETAS Ltd operate such a Scheme
and a listing of their Registered Competent Persons can be found on
their website at www.hetas.co.uk.
CO Alarms
:
Building regulations require that when ever a new or replacement
fixed solid fuel or wood/biomass appliance is installed in a dwelling a
carbon monoxide alarm must be fitted in the same room as the ap
-
pliance. Further guidance on the installation of the carbon monoxide
alarm is available in BS EN 50292:2002 and from the alarm manu-
facturer’s instructions. Provision of an alarm must not be considered
a substitute for either installing the appliance correctly or ensuring
regular servicing and maintenance of the appliance and chimney
system.