background image

12

    

TT22H

 

TT22HS

Nominal heat output  

7,5 kW  

7,5 kW 

Height:   1093mm 

1093mm

Width: 

   756mm 756mm

Depth: 

   476mm 476mm

Weight: 

 

 

ca. 190kg 

ca. 250kg

Average values for testing of TT22 models:

Exhaust gas temperature 

259 °C

Exhaust gas mass flow 

6,2 g/s

Efficiency 

 

 

82%

Nominal Heat output  

7,5 kW

Flue draught   

 

12 Pa

SUPPLEMENTARY INSTRUCKTIONS UK
READ THE INSTRUCTION BOOKLET AND THESE SUPPLEMEN-

TARY INSTRUCTIONS CAREFULLY BEFORE INSTALLATION

These instructions together with those in the instruction booklet co-

ver the basic principles to ensure the satisfactory installation of the 

stove, although detail may need slight modification to suit particular 

local site conditions.

In all cases the installation must comply with current Building Regu-

lations, Local Authority Byelaws and other specifications or regulati

-

ons as they affect the installation of the stove.

It should be noted that the Building Regulations requirements may 

be met by adopting the relevant recommendations given in British 

Standards BS 8303, BS EN 15287-1:2007 as an alternative means 

to achieve an equivalent level of performance to that obtained fol-

lowing the guidance given in Approved Document J.
Please note that it is a legal requirement under England and Wales 

Building Regulations that the installation of the stove is either car-

ried out under Local Authority Building Control approval or is instal-

led by a Competent Person registered with a Government approved 

Competent Persons Scheme. HETAS Ltd operate such a Scheme 

and a listing of their Registered Competent Persons can be found on 

their website at www.hetas.co.uk. 

CO Alarms

:

Building regulations require that when ever a new or replacement 

fixed solid fuel or wood/biomass appliance is installed in a dwelling a 

carbon monoxide alarm must be fitted in the same room as the ap

-

pliance. Further guidance on the installation of the carbon monoxide 

alarm is available in BS EN 50292:2002 and from the alarm manu-

facturer’s instructions. Provision of an alarm must not be considered 

a substitute for either installing the appliance correctly or ensuring 

regular servicing and maintenance of the appliance and chimney 

system.

Содержание TT22

Страница 1: ...TT22S TT22H TT22HS Please read also SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR THE UK MARKET last 6 pages CE approved according to DS EN13240 DS Danish Standard DIN Deutsche Industrienorm SINTEF Norw...

Страница 2: ...meant to heat over at night By following the instruction below in Lighting instructions the best and most environmentally friendly combustion is achieved The wood burning stove is delivered ready for...

Страница 3: ...and clean wood for combustion in the wood burning stove Maximum size of logs used in the stove is up to 50 cm in length and 10 cm in diameter Maximum filling Wood must not be added to the wood burning...

Страница 4: ...an air valve in the room s outer wall Air valves that supply necessary combustion air must be kept free from blockage An exhaust fan in the same room or close to the wood burning stove can also have...

Страница 5: ...s crucial to the stove working as intended and burns as en vironmentally friendly as possible The height of the chimney must typically be a minimum of 3 5 m from the top of the stove to the top of the...

Страница 6: ...the given chimney Firewood amount and damper setting can be adjusted to the individual need for heating and the draught in the concrete chimney On your new TT22 TT22S the work with controlling the ai...

Страница 7: ...nce a year the stove should get thorough maintenance The combustion chamber should be clea ned for ashes and soot and the door hinges and the closing mecha nism should be lubricated with copper grease...

Страница 8: ...peration of the wood burner TermaTech offers a 5 year warranty on material and manufacturing faults on the load bearing frame exclusive of the combustion cham ber Combustion chamber The following part...

Страница 9: ...uct or replaced part Apart from the above warranty rules the consumer also has those rights which are evident from the obligatory consumer legislation Any fault or defect must be examined by the vendo...

Страница 10: ...he chimney This also gives lower exploitation and harms the environment So it is a balance that is quite easy to find with a little practise See also below under Storage Bio briquettes can be used but...

Страница 11: ...wind directions The chimney may be too short for the ridge or trees may have grown and are creating turbulence Remember not to open the door while there are flames The stove is difficult to light and...

Страница 12: ...British Standards BS 8303 BS EN 15287 1 2007 as an alternative means to achieve an equivalent level of performance to that obtained fol lowing the guidance given in Approved Document J Please note tha...

Страница 13: ...n solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The TermaTech TT22 TT22S ha...

Страница 14: ...t J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or t...

Страница 15: ...not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non combustible he arth of a size and construction that is in accordance...

Страница 16: ...fumes be emitted from the stove The customer should be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons READ THE INSTRUCTION BOOK AND...

Страница 17: ...n to ensure that any softer deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove In situations where it is not possible to sweep...

Страница 18: ...cable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade should be called i...

Страница 19: ...19 Damper control unit for smoke control areas...

Страница 20: ...maTech AS DK 8260 Viby J UK This installation and user guide with related claim and war ranty provisions concerns TermaTech wood burning stove Model ___________ Productions serialnumber Purchased on 9...

Отзывы: