background image

5

For inflammable material like inflammable walls made of wood, fur

-

niture, etc. the following minimum distances apply for safety rea-

sons:

150 mm behind the stove to flammable material.  (picture 1)

450 mm beside the stove to flammable material. (picture 1)

200 mm behind/beside if mounted 45° in a corner (picture 2)

1200 mm in front of the stove to flammable material.

Distance to non-flammable materials

It is recommended that there is a minimum of 50-100 mm behind 

and beside the stove so the stove can dispose of the heat, this di-

stance makes cleaning of and around the stove easier. In addition, 

refer to the relevant Building Regulations.

Requirements for the chimney

The chimney must be of sufficient height so the draught conditions 

are okay the smoke does not bother anyone. Good draught in the 

chimney is crucial to the stove working as intended and burns as en-

vironmentally friendly as possible. The height of the chimney must 

typically be a minimum of 3.5 m from the top of the stove to the top 

of the chimney.

The chimney must have a minimum internal diameter of Ø150mm. 

The chimney must be equipped with an easily accessible cleaning 

hatch. All joints and connections must be tight and the chimney 

must be able to provide a draught of at least 1.2 mm water gauge 

(12Pa). 
It is possible to connect the wood-burning stove to chimneys that 

are also used for other purposes. However, the concrete conditions 

must be assessed by the fitter and/or chimney sweep.

If the stove is to be mounted with back/rear exit the follo-

wing is done: 

The round, welded or screwed cover plate at the back of the stove 

is removed. Then the cut-out piece on the base-plate is removed 

(the thin division plate). Be careful not to drop the piece between 

the back plate and the stove! This is best done with a screwdriver / 

chisel or pliers.

Содержание TT22

Страница 1: ...TT22S TT22H TT22HS Please read also SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR THE UK MARKET last 6 pages CE approved according to DS EN13240 DS Danish Standard DIN Deutsche Industrienorm SINTEF Norw...

Страница 2: ...meant to heat over at night By following the instruction below in Lighting instructions the best and most environmentally friendly combustion is achieved The wood burning stove is delivered ready for...

Страница 3: ...and clean wood for combustion in the wood burning stove Maximum size of logs used in the stove is up to 50 cm in length and 10 cm in diameter Maximum filling Wood must not be added to the wood burning...

Страница 4: ...an air valve in the room s outer wall Air valves that supply necessary combustion air must be kept free from blockage An exhaust fan in the same room or close to the wood burning stove can also have...

Страница 5: ...s crucial to the stove working as intended and burns as en vironmentally friendly as possible The height of the chimney must typically be a minimum of 3 5 m from the top of the stove to the top of the...

Страница 6: ...the given chimney Firewood amount and damper setting can be adjusted to the individual need for heating and the draught in the concrete chimney On your new TT22 TT22S the work with controlling the ai...

Страница 7: ...nce a year the stove should get thorough maintenance The combustion chamber should be clea ned for ashes and soot and the door hinges and the closing mecha nism should be lubricated with copper grease...

Страница 8: ...peration of the wood burner TermaTech offers a 5 year warranty on material and manufacturing faults on the load bearing frame exclusive of the combustion cham ber Combustion chamber The following part...

Страница 9: ...uct or replaced part Apart from the above warranty rules the consumer also has those rights which are evident from the obligatory consumer legislation Any fault or defect must be examined by the vendo...

Страница 10: ...he chimney This also gives lower exploitation and harms the environment So it is a balance that is quite easy to find with a little practise See also below under Storage Bio briquettes can be used but...

Страница 11: ...wind directions The chimney may be too short for the ridge or trees may have grown and are creating turbulence Remember not to open the door while there are flames The stove is difficult to light and...

Страница 12: ...British Standards BS 8303 BS EN 15287 1 2007 as an alternative means to achieve an equivalent level of performance to that obtained fol lowing the guidance given in Approved Document J Please note tha...

Страница 13: ...n solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The TermaTech TT22 TT22S ha...

Страница 14: ...t J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or t...

Страница 15: ...not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non combustible he arth of a size and construction that is in accordance...

Страница 16: ...fumes be emitted from the stove The customer should be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons READ THE INSTRUCTION BOOK AND...

Страница 17: ...n to ensure that any softer deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove In situations where it is not possible to sweep...

Страница 18: ...cable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade should be called i...

Страница 19: ...19 Damper control unit for smoke control areas...

Страница 20: ...maTech AS DK 8260 Viby J UK This installation and user guide with related claim and war ranty provisions concerns TermaTech wood burning stove Model ___________ Productions serialnumber Purchased on 9...

Отзывы: