background image

9

as the varnish

• 

similar circumstances which are not due to material or manufac-

turing faults

 

The lesser defects below, which cannot underlie any claim, can occur 

in the product:

• 

naturally occurring variations in the colour nuances and marbling 

on the soapstone, sandstone and other stone cladding.

• 

sounds which occur during burning are normal, this occurs when 

metal expands/retracts.

 

If a fault occurs during delivery to the customer, or if such a fault 

arises during the warranty period which is covered by this warranty, 

TermaTech A/S agrees to send a suitable replacement part free of 

charge to rectify the fault. Any additional obligation of TermaTech 

A/S to remedy the fault, for example, in the form of installation of 

the replacement part, does not exist. 

In addition the purchaser has, apart from the right to a replacement 

part, no right to either direct or indirect damages.

 

Repairs of faults or replacement of parts on the product do not 

extend the product or replacement part’s warranty period. Neither 

does a new warranty period begin for the product or replaced part.

 

Apart from the above warranty rules, the consumer also has those 

rights which are evident from the obligatory consumer legislation

 

Any fault or defect must be examined by the vendor who has sold 

the product. In this case the purchaser must be able to prove that 

the product has been purchased via the vendor and when it was 

purchased, for example, in the form of an invoice/receipt. The 

purchaser must specify the model and production number, which is 

stated on the product. If the purchaser wishes to refer to a fault, 

the vendor must be informed within a reasonable time, i.e. 14 days 

after the defect has been ascertained. 

HINTS
Lighting after long break

If the stove has not been used for a long time the chimney should 

be checked for possible blockage before lighting. Furthermore it is 

a good idea to remove any dust from the wood-burning stove as it 

might smell after a long break.

Chimney fire

In case of chimney fire the doors, drawers and damper of the wood-

burning stove must be closed immediately in order to shut of the 

supply of oxygen. The relevant authorities must be notified if neces

-

sary. The stove must not be used until the chimney has been in-

spected.

Kindling

 is the designation for finely split wood/sticks that are 

Содержание TT22

Страница 1: ...TT22S TT22H TT22HS Please read also SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR THE UK MARKET last 6 pages CE approved according to DS EN13240 DS Danish Standard DIN Deutsche Industrienorm SINTEF Norw...

Страница 2: ...meant to heat over at night By following the instruction below in Lighting instructions the best and most environmentally friendly combustion is achieved The wood burning stove is delivered ready for...

Страница 3: ...and clean wood for combustion in the wood burning stove Maximum size of logs used in the stove is up to 50 cm in length and 10 cm in diameter Maximum filling Wood must not be added to the wood burning...

Страница 4: ...an air valve in the room s outer wall Air valves that supply necessary combustion air must be kept free from blockage An exhaust fan in the same room or close to the wood burning stove can also have...

Страница 5: ...s crucial to the stove working as intended and burns as en vironmentally friendly as possible The height of the chimney must typically be a minimum of 3 5 m from the top of the stove to the top of the...

Страница 6: ...the given chimney Firewood amount and damper setting can be adjusted to the individual need for heating and the draught in the concrete chimney On your new TT22 TT22S the work with controlling the ai...

Страница 7: ...nce a year the stove should get thorough maintenance The combustion chamber should be clea ned for ashes and soot and the door hinges and the closing mecha nism should be lubricated with copper grease...

Страница 8: ...peration of the wood burner TermaTech offers a 5 year warranty on material and manufacturing faults on the load bearing frame exclusive of the combustion cham ber Combustion chamber The following part...

Страница 9: ...uct or replaced part Apart from the above warranty rules the consumer also has those rights which are evident from the obligatory consumer legislation Any fault or defect must be examined by the vendo...

Страница 10: ...he chimney This also gives lower exploitation and harms the environment So it is a balance that is quite easy to find with a little practise See also below under Storage Bio briquettes can be used but...

Страница 11: ...wind directions The chimney may be too short for the ridge or trees may have grown and are creating turbulence Remember not to open the door while there are flames The stove is difficult to light and...

Страница 12: ...British Standards BS 8303 BS EN 15287 1 2007 as an alternative means to achieve an equivalent level of performance to that obtained fol lowing the guidance given in Approved Document J Please note tha...

Страница 13: ...n solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The TermaTech TT22 TT22S ha...

Страница 14: ...t J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or t...

Страница 15: ...not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non combustible he arth of a size and construction that is in accordance...

Страница 16: ...fumes be emitted from the stove The customer should be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons READ THE INSTRUCTION BOOK AND...

Страница 17: ...n to ensure that any softer deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove In situations where it is not possible to sweep...

Страница 18: ...cable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade should be called i...

Страница 19: ...19 Damper control unit for smoke control areas...

Страница 20: ...maTech AS DK 8260 Viby J UK This installation and user guide with related claim and war ranty provisions concerns TermaTech wood burning stove Model ___________ Productions serialnumber Purchased on 9...

Отзывы: