background image

18

If there is insufficient burning material in the firebed to light a new 

fuel charge, excessive smoke emission can occur.  Refuelling must 

be carried out onto a sufficient quantity of glowing embers and ash 

that the new fuel charge will ignite. If the fire bed is too low or cool, 

suitable kindling must be used to re-light fires

 

Fuel overloading

The maximum amount of fuel specified in this manual should not be 

exceeded, overloading can cause excess smoke.

Use with door left open

Operation with the door open can cause excess smoke. The appli-

ance must not be operated with the appliance door left open except 

as directed in the instructions.

Dampers left open

Operation with the air controls or dampers open can cause excess 

smoke. The appliance must not be operated with air controls or 

dampers left open except as directed in the instructions.

Chimney Fires

If the chimney is thoroughly and regularly swept, chimney fires 

should not occur.  However, if a chimney fire does occur turn off the 

stove immediately and isolate the mains electricity supply (if appli-

cable), and tightly close the doors of the stove.  This should cause 

the chimney fire to go out. If the chimney fire does not go out when 

the above action is taken then the fire brigade should be called im

-

mediately. Do not relight the stove until the chimney and flueways 

have been cleaned and examined by a professional.

Permanent air vent

The stove requires a permanent and adequate air supply in order for 

it to operate safely and efficiently.

In accordance with current Building Regulations the installer may 

have fitted a permanent air supply vent into the room in which the 

stove is installed to provide combustion air. This air vent should not 

under any circumstances be shut off or sealed.

USER OPERATING INSTRUCTIONS

Please read the important notices given above before referring to 

the main instruction book for detailed operating instructions.

Recommended fuels

Stoves may be designed to burn dry seasoned wood logs and/or 

solid mineral fuel as indicated in the main stove manuals.

HETAS Ltd Approval

HETAS approval may be limited to specific fuel types as detailed in 

the main instruction manuals. Approval does not cover the use of 

other fuels either alone or mixed with the recommended fuel, nor 

does it cover instructions for the use of other fuels.

Содержание TT22

Страница 1: ...TT22S TT22H TT22HS Please read also SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR THE UK MARKET last 6 pages CE approved according to DS EN13240 DS Danish Standard DIN Deutsche Industrienorm SINTEF Norw...

Страница 2: ...meant to heat over at night By following the instruction below in Lighting instructions the best and most environmentally friendly combustion is achieved The wood burning stove is delivered ready for...

Страница 3: ...and clean wood for combustion in the wood burning stove Maximum size of logs used in the stove is up to 50 cm in length and 10 cm in diameter Maximum filling Wood must not be added to the wood burning...

Страница 4: ...an air valve in the room s outer wall Air valves that supply necessary combustion air must be kept free from blockage An exhaust fan in the same room or close to the wood burning stove can also have...

Страница 5: ...s crucial to the stove working as intended and burns as en vironmentally friendly as possible The height of the chimney must typically be a minimum of 3 5 m from the top of the stove to the top of the...

Страница 6: ...the given chimney Firewood amount and damper setting can be adjusted to the individual need for heating and the draught in the concrete chimney On your new TT22 TT22S the work with controlling the ai...

Страница 7: ...nce a year the stove should get thorough maintenance The combustion chamber should be clea ned for ashes and soot and the door hinges and the closing mecha nism should be lubricated with copper grease...

Страница 8: ...peration of the wood burner TermaTech offers a 5 year warranty on material and manufacturing faults on the load bearing frame exclusive of the combustion cham ber Combustion chamber The following part...

Страница 9: ...uct or replaced part Apart from the above warranty rules the consumer also has those rights which are evident from the obligatory consumer legislation Any fault or defect must be examined by the vendo...

Страница 10: ...he chimney This also gives lower exploitation and harms the environment So it is a balance that is quite easy to find with a little practise See also below under Storage Bio briquettes can be used but...

Страница 11: ...wind directions The chimney may be too short for the ridge or trees may have grown and are creating turbulence Remember not to open the door while there are flames The stove is difficult to light and...

Страница 12: ...British Standards BS 8303 BS EN 15287 1 2007 as an alternative means to achieve an equivalent level of performance to that obtained fol lowing the guidance given in Approved Document J Please note tha...

Страница 13: ...n solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The TermaTech TT22 TT22S ha...

Страница 14: ...t J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or t...

Страница 15: ...not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non combustible he arth of a size and construction that is in accordance...

Страница 16: ...fumes be emitted from the stove The customer should be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons READ THE INSTRUCTION BOOK AND...

Страница 17: ...n to ensure that any softer deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove In situations where it is not possible to sweep...

Страница 18: ...cable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade should be called i...

Страница 19: ...19 Damper control unit for smoke control areas...

Страница 20: ...maTech AS DK 8260 Viby J UK This installation and user guide with related claim and war ranty provisions concerns TermaTech wood burning stove Model ___________ Productions serialnumber Purchased on 9...

Отзывы: