The Clean Air Act 1993 and Smoke Control Areas

Under the Clean Air Act local authorities may declare the whole or 

part of the district of the authority to be a smoke control area. It 

is an offence to emit smoke from a chimney of a building, from a 

furnace or from any fixed boiler if located in a designated smoke 

control area. It is also an offence to acquire an ”unauthorised fuel” 

for use within a smoke control area unless it is used in an ”exempt” 

appliance (”exempted” from the controls which generally apply in 

the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs has 

powers under the Act to authorise smokeless fuels or exempt ap-

pliances for use in smoke control areas in England. In Scotland and 

Wales this power rests with Ministers in the devolved administrati-

ons for those countries. Separate legislation, the Clean Air (Northern 

Ireland) Order 1981, applies in Northern Ireland. Therefore it is a 

requirement that fuels burnt or obtained for use in smoke control 

areas have been ”authorised” in Regulations and that appliances 

used to burn solid fuel in those areas (other than ”authorised” fuels) 

have been exempted by an Order made and signed by the Secretary 

of State or Minister in the devolved administrations.
The TermaTech TT22, TT22S have been recommended as suitable for 

use in smoke control areas when burning wood logs and when fitted 

with a smoke control kit to fix the primary air control at 250mm2 

and secondary air control at 440mm2 in their minimum position
Further information on the requirements of the Clean Air Act can be 

found here: 

http://smokecontrol.defra.gov.uk/

HEALTH AND SAFETY PRECAUTIONS

Special care must be taken when installing the stove such that the 

requirements of the Health and Safety at Work Act are met.

Handling

Adequate facilities must be available for loading, unloading and site 

handling.

Fire Cement

Some types of fire cement are caustic and should not be allowed to 

come into contact with the skin.  In case of contact wash immedia-

tely with plenty of water.

Asbestos

This stove contains no asbestos. If there is a possibility of disturbing 

any asbestos in the course of installation then please seek specialist 

guidance and use appropriate protective equipment.

Metal Parts

When installing or servicing this stove care should be taken to avoid 

the possibility of personal injury.

Содержание TT22

Страница 1: ...TT22S TT22H TT22HS Please read also SUPPLEMENTARY INSTALLATION INSTRUCTIONS FOR THE UK MARKET last 6 pages CE approved according to DS EN13240 DS Danish Standard DIN Deutsche Industrienorm SINTEF Norw...

Страница 2: ...meant to heat over at night By following the instruction below in Lighting instructions the best and most environmentally friendly combustion is achieved The wood burning stove is delivered ready for...

Страница 3: ...and clean wood for combustion in the wood burning stove Maximum size of logs used in the stove is up to 50 cm in length and 10 cm in diameter Maximum filling Wood must not be added to the wood burning...

Страница 4: ...an air valve in the room s outer wall Air valves that supply necessary combustion air must be kept free from blockage An exhaust fan in the same room or close to the wood burning stove can also have...

Страница 5: ...s crucial to the stove working as intended and burns as en vironmentally friendly as possible The height of the chimney must typically be a minimum of 3 5 m from the top of the stove to the top of the...

Страница 6: ...the given chimney Firewood amount and damper setting can be adjusted to the individual need for heating and the draught in the concrete chimney On your new TT22 TT22S the work with controlling the ai...

Страница 7: ...nce a year the stove should get thorough maintenance The combustion chamber should be clea ned for ashes and soot and the door hinges and the closing mecha nism should be lubricated with copper grease...

Страница 8: ...peration of the wood burner TermaTech offers a 5 year warranty on material and manufacturing faults on the load bearing frame exclusive of the combustion cham ber Combustion chamber The following part...

Страница 9: ...uct or replaced part Apart from the above warranty rules the consumer also has those rights which are evident from the obligatory consumer legislation Any fault or defect must be examined by the vendo...

Страница 10: ...he chimney This also gives lower exploitation and harms the environment So it is a balance that is quite easy to find with a little practise See also below under Storage Bio briquettes can be used but...

Страница 11: ...wind directions The chimney may be too short for the ridge or trees may have grown and are creating turbulence Remember not to open the door while there are flames The stove is difficult to light and...

Страница 12: ...British Standards BS 8303 BS EN 15287 1 2007 as an alternative means to achieve an equivalent level of performance to that obtained fol lowing the guidance given in Approved Document J Please note tha...

Страница 13: ...n solid fuel in those areas other than authorised fuels have been exempted by an Order made and signed by the Secretary of State or Minister in the devolved administrations The TermaTech TT22 TT22S ha...

Страница 14: ...t J If installation is into an existing chimney then it must be sound and have no cracks or other faults which might allow fumes into the house Older properties especially may have chimney faults or t...

Страница 15: ...not independently supported The weight of the stove is indicated in the brochure The stove should preferably be installed on a non combustible he arth of a size and construction that is in accordance...

Страница 16: ...fumes be emitted from the stove The customer should be warned to use a fireguard to BS 8423 2002 Replaces BS 6539 in the presence of children aged and or infirm persons READ THE INSTRUCTION BOOK AND...

Страница 17: ...n to ensure that any softer deposits left from the open fire usage have not been loosened by the higher flue temperatures generated by the closed stove In situations where it is not possible to sweep...

Страница 18: ...cable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go out when the above action is taken then the fire brigade should be called i...

Страница 19: ...19 Damper control unit for smoke control areas...

Страница 20: ...maTech AS DK 8260 Viby J UK This installation and user guide with related claim and war ranty provisions concerns TermaTech wood burning stove Model ___________ Productions serialnumber Purchased on 9...

Отзывы: