69
EN
EXPERT SETTINGS
ACCESS
To access the Expert settings in 5 steps, enter the Auto, Comfort, Eco or Frost protection mode, then:
Information display
1
Information displays
1
Press for 5
seconds
1
Press briefly
twice
2
Long and simultaneous
10 seconds press
4
Press for 10
seconds
3
Press briefly
5
Information displays
Pro
=
Expert settings
Setting sequence:
Ambient temperature sensor adjustement
→
Setting the energy type
→
Setting the power
→
Internal temperature
monitoring
→
Restoring factory settings
AMBIENT TEMPERATURE SENSOR
ADJUSTEMENT
OVERVIEW
Use this function if the measured temperature (measured
by another reliable thermometer) differs by at least 1°C
or 2°C compared to the set temperature of the radiator.
The calibration adjusts the temperature measured by the
ambient temperature sensor to compensate for a deviation
from + 5°C to - 5°C by intervals of 0.1°C.
AMBIENT TEMPERATURE SENSOR ADJUSTEMENT
①
If the room temperature difference is negative.
Example:
Setting temperature (expected) = 24°C.
Ambient temperature (reading on a reliable thermom-
eter) = 22°C.
Difference measured = -2°C.
Important:
Before carrying out the calibration it is rec-
ommended to wait for 4h after the setting temperature
modification to insure that the ambient temperature is
stabilized.
IMPORTANT: THIS OPERATION IS RESERVED FOR PROFESSIONAL INSTALLERS ONLY; ANY WRONG CHANGES WOULD
RESULT IN CONTROL ANOMALIES.