64
⑭
You can set the Boost maximum temperature by
pressing
or
from 25°C to 39°C by intervals
of 1°C.
⑮
To save and move automatically to the next setting,
press
. To exit the user settings, press
twice.
SETTING THE TEMPERATURE UNIT
The pre-set temperature unit is degrees Celsius. This
setting cannot be changed on this version.
⑯
To move automatically to the next setting, press
.
To exit the user settings, press
twice.
RESTORING FACTORY SETTINGS
To return to the factory settings, follow these steps:
①
From the setting of the temperature unit, press
.
rest
appears on the display.
②
NO
appears. Press
or
to select
YES
.
yes
= Factory settings reset
NO
= Factory settings not reset
③
Press the key
for 5 seconds. The device returns
to its initial configuration and goes back automatically
to the home display of the user settings.
5 sec.
The following parameter values will be restored:
Parameters
Factory settings
Operating
Comfort setting temperature
19°C
Boost duration
60 min.
Keypad lock
Disabled
Backlighting
Backlighting
L3
Eco mode temperature lowering-level -3,5°C
Frost protection temperature
7°C
Super Comfort
Enabled
Minimum set of Comfort setting
temperature
7°C
Maximum set of Comfort setting
temperature
30°C
Maximal Boost duration
60 min.
Maximum ambient temperature for
the automatic stop of the Boost
35°C
Temperature unit
°C
Press
to exit the user settings.
Содержание WEBL1K906F
Страница 41: ...41 EN ...
Страница 78: ......
Страница 79: ......
Страница 80: ...TERMA Sp z o o Czaple 100 80 298 Gdańsk Poland terma termagroup pl www termagroup pl 20200529WOLKA MPGKE 385 ...