Right Forward Threshold
not calibrated
Propel automatically limited to default threshold
parameters
If threshold < 4000, limit to 4000, If > 6000, limit
to 6000
Threshold needs to be calibrated
Perform threshold calibration procedure
Right Reverse Threshold
not calibrated
Propel automatically limited to default threshold
parameters
If threshold < 4000, limit to 4000, If > 6000, limit
to 6000
Threshold needs to be calibrated
Perform threshold calibration procedure
Left Forward high speed
End Current
not calibrated
Propel automatically limited to default parameter
setting
(If parameter is out of range, limits to max current,
15030)
End current needs to be calibrated
Perform end current calibration procedure
Left Forward low speed
End Current
not calibrated
Propel automatically limited to default parameter
setting
(If parameter is out of range, limits to max current,
15030)
End current needs to be calibrated
Perform end current calibration procedure
Left Reverse high speed
End Current
not calibrated
Propel automatically limited to default parameter
setting
(If parameter is out of range, limits to max current,
15030)
End current needs to be calibrated
Perform end current calibration procedure
Left Reverse low speed
End Current
not calibrated
Propel automatically limited to default parameter
setting
(If parameter is out of range, limits to max current,
15030)
End current needs to be calibrated
Perform end current calibration procedure
Right Forward high speed
End Current
not calibrated
Propel automatically limited to default parameter
setting
(If parameter is out of range, limits to max current,
15030)
End current needs to be calibrated
Perform end current calibration procedure
Right Forward low speed
End Current
not calibrated
Propel automatically limited to default parameter
setting
(If parameter is out of range, limits to max current,
15030)
End current needs to be calibrated
Perform end current calibration procedure
Right Reverse high speed
End Current
not calibrated
Propel automatically limited to default parameter
setting
(If parameter is out of range, limits to max current,
15030)
End current needs to be calibrated
Perform end current calibration procedure
Right Reverse low speed
End Current
not calibrated
Propel automatically limited to default parameter
setting
(If parameter is out of range, limits to max current,
15030)
End current needs to be calibrated
Perform end current calibration procedure
Brake Solenoid
short circuit
Propel disabled (ramp to stop)
Faulty connections or wires to or from brake
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Brake Solenoid
short circuit (to power)
Propel disabled (ramp to stop)
Faulty connections or wires to or from brake
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Brake Solenoid
open circuit (to ground)
Propel disabled (ramp to stop)
Faulty connections or wires to or from brake
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Drive Enable Solenoid
short circuit (to power)
Propel disabled
Faulty connections or wires to or from drive
enable solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Drive Enable Solenoid
short circuit (to ground
Propel disabled
Faulty connections or wires to or from drive
enable solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
Drive Enable Solenoid
open circuit
Propel disabled
Faulty connections or wires to or from drive
enable solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
2-Speed Solenoid
fault
High range propel disabled
Faulty connections or wires to or from 2-speed
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Left Fwd Solenoid
short circuit
Propel disabled
(de-energizes drive enable solenoid)
Faulty connections or wires to or from left fwd
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Left Fwd Solenoid
short circuit
Propel disabled
(de-energizes drive enable solenoid)
Faulty connections or wires to or from left fwd
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Left Fwd Solenoid
open circuit
Machine stops immediately and returns to neutral.
Forward propel is disabled and reverse propel is
limited to parameter setting (Default 50%)
Faulty connections or wires to or from left fwd
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Left Rvs Solenoid
short circuit
Propel disabled
(de-energizes drive enable solenoid)
Faulty connections or wires to or from left reverse
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Left Rvs Solenoid
short circuit
Propel disabled
(de-energizes drive enable solenoid)
Faulty connections or wires to or from left reverse
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Left Rvs Solenoid
open circuit
Machine stops immediately and returns to neutral.
Reverse is disabled and forward propel is limited
to parameter setting (Default 50%)
Faulty connections or wires to or from left reverse
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Right Fwd Solenoid
short circuit
Propel disabled
(de-energizes drive enable solenoid)
Faulty connections or wires to or from right fwd
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
Right Fwd Solenoid
short circuit
Propel disabled
(de-energizes drive enable solenoid)
Faulty connections or wires to or from right fwd
solenoid, faulty solenoid.
Restore connections, replace faulty compoents,
then cycle power by turning the key off then back
on
18-5
Compact Track Loader
18. Troubleshooting
Propel (continued)
Содержание PT100G Forestry
Страница 1: ...PT 100G PT 100G Forestry Part Number 2076 286 Printed 8 10 Service Manual Compact Track Loader...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 14: ......
Страница 20: ...Hydraulic Solenoid Blocks Figure 3 6 PT 100G Hyd Solenoid blocks 3 6 Compact Track Loader 3 Circuit Diagrams...
Страница 22: ......
Страница 40: ......
Страница 52: ......
Страница 62: ......
Страница 66: ......
Страница 80: ......
Страница 98: ......
Страница 102: ......
Страница 116: ......
Страница 136: ......
Страница 138: ......
Страница 140: ......
Страница 141: ......
Страница 142: ...Terex Construction Americas 8800 Rostin Road Southaven MS 38671 888 201 6008 662 393 1800 www terex com...