March 2021
Service and Repair Manual
Manifolds
Part No. 1272217GT
GS
™
-30 • 32 • 46 • 47
61
5-5
Lift Pressure Selector Manifold Components – GS-4047
The lift pressure selector manifold is mounted behind an inspection door, at the ground control side of the
machine.
Index No. Description
Schematic Item
Function
Torque
—
Coil nut (item DN)
—
—
4-5 ft-lbs / 5-7 Nm
—
Plug
—
—
13 ft-lbs / 18 Nm
1
Lift pressure selector valve, 200 psi /
138 bar
DM
Lift relief
20 ft-lbs / 27 Nm
2
Solenoid valve, 2 position 2 way
DN
Lift circuit
20 ft-lbs / 27 Nm
Note: 'alpha' callouts refer to corresponding notes on the hydraulic schematic.
Note: 'alpha-numeric' callouts refer to corresponding notes on the electrical schematic.
How to Install a Valve Cartridge
1 Dip the cartridge in clean oil to lube the O-rings.
2 Screw the cartridge in by hand until the top O-ring is met, then torque to specifications.
3 If required, install the valve coil(s) onto the valve stem. Install the coil nut onto the valve stem and
torque to specifications.
Содержание Genie GS-1530
Страница 205: ...March 2021 Service and Repair Manual Wiring Diagram Ground and Platform Controls Part No 1272217GT GS 30 32 46 47 189 ...
Страница 243: ...March 2021 Service and Repair Manual 227 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 246: ...Service and Repair Manual March 2021 230 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 297: ...March 2021 Service and Repair Manual 281 Electrical Schematic GS 3232 AS CE from serial number GS3216P 146463 ...
Страница 300: ...Service and Repair Manual March 2021 284 Electrical Schematic GS 3232 AS CE from serial number GS3216P 143463 ...
Страница 337: ...March 2021 Service and Repair Manual 321 Electrical Schematic GS 4047 AS CE from serial number GS4716D 3102 ...
Страница 339: ...March 2021 Service and Repair Manual 323 Electrical Schematic Foot Switch option All Models ...
Страница 341: ......