Service and Repair Manual
March 2021
Type "PXXX" Faults
170
GS
™
-30 • 32 • 46 • 47
Part No. 1272217GT
Type "PXXX" Faults
DTC
Number
Message on
GCON LCD
Description
Possible Causes
Failure Mode
P001:
GS30,
GS32,
GS46 &
GS47
P001:PWR FAULT
SW PWR1:BAT-
Short circuit of the switched power #1
circuit to battery negative.
• Short circuit in switched power #1, down limit
switch, pothole limit switch, digital tilt switch
harness.
• GCON ECM.
All functions
inhibited.
P003:
GS30,
GS32,
GS46 &
GS47
P003:PWR FAULT
SW PWR1:BAT+
Short circuit of the switched power #1
circuit to battery positive.
• Short circuit in switched power #1, down limit
switch, pothole limit switch, digital tilt switch
harness.
• GCON ECM.
All functions
inhibited.
P004:
GS30,
GS32,
GS46 &
GS47
P004:DEVICEFAULT
HORN:BAT-
Short circuit of the automotive horn circuit to
battery negative.
• Short circuit in automotive horn harness.
• Automotive horn short circuit.
• GCON ECM.
Automotive horn
inhibited.
P005:
GS30,
GS32,
GS46 &
GS47
P005:DEVICEFAULT
HORN:OPEN
Open circuit of the automotive horn circuit.
• Open circuit in automotive horn harness.
• Automotive horn open circuit.
• GCON ECM.
Automotive horn
inhibited.
P006:
GS30,
GS32,
GS46 &
GS47
P006:DEVICEFAULT
HORN:BAT+
Short circuit of the automotive horn circuit to
battery positive.
• Short circuit in automotive horn harness.
• Automotive horn short circuit.
• GCON ECM.
Automotive horn
inhibited.
P007:
GS30,
GS32,
GS46 &
GS47
P007:DEVICEFAULT
GCON ALARM:BAT-
Short circuit of the GCON alarm circuit to
battery negative.
• Short circuit in GCON alarm harness.
• GCON alarm short circuit.
• GCON ECM.
GCON alarm
inhibited.
P009:
GS30,
GS32,
GS46 &
GS47
P009:DEVICEFAULT
GCON ALARM:BAT+
Short circuit of the GCON alarm circuit to
battery positive.
• Short circuit in GCON alarm harness.
• GCON alarm short circuit.
• GCON ECM.
GCON alarm
inhibited.
P013:
GS30,
GS32,
GS46 &
GS47
P013:PWR FAULT
PCON PWRET:BAT-
Short circuit of the PCON power return
circuit to battery negative.
• Short circuit in PCON power return harness.
• GCON ECM.
All functions
inhibited.
P015:
GS30,
GS32,
GS46 &
GS47
P015:PWR FAULT
PCON PWRET:BAT+
Short circuit of the PCON power return
circuit to battery positive.
• Short circuit in PCON power return harness.
• GCON ECM.
All functions
inhibited.
P018:
GS30,
GS32,
GS46 &
GS47
018:PWR FAULT
PCON POWER:BAT-
Short circuit of the PCON power circuit to
battery negative.
• Short circuit in PCON power harness.
• GCON ECM.
All functions
inhibited.
P019:
GS30,
GS32,
GS46 &
GS47
018:PWR FAULT
PCON POWER:BAT+
Short circuit of the PCON power circuit to
battery positive.
• Short circuit in PCON power harness.
• GCON ECM.
All functions
inhibited.
Содержание Genie GS-1530
Страница 205: ...March 2021 Service and Repair Manual Wiring Diagram Ground and Platform Controls Part No 1272217GT GS 30 32 46 47 189 ...
Страница 243: ...March 2021 Service and Repair Manual 227 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 246: ...Service and Repair Manual March 2021 230 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 297: ...March 2021 Service and Repair Manual 281 Electrical Schematic GS 3232 AS CE from serial number GS3216P 146463 ...
Страница 300: ...Service and Repair Manual March 2021 284 Electrical Schematic GS 3232 AS CE from serial number GS3216P 143463 ...
Страница 337: ...March 2021 Service and Repair Manual 321 Electrical Schematic GS 4047 AS CE from serial number GS4716D 3102 ...
Страница 339: ...March 2021 Service and Repair Manual 323 Electrical Schematic Foot Switch option All Models ...
Страница 341: ......