![Terex Genie GS-1530 Скачать руководство пользователя страница 194](http://html.mh-extra.com/html/terex/genie-gs-1530/genie-gs-1530_service-and-repair-manual_1088648194.webp)
Service and Repair Manual
March 2021
Type "CXXX" Faults
178
GS
™
-30 • 32 • 46 • 47
Part No. 1272217GT
Type "CXXX" Faults
DTC
Number
Message on
GCON LCD
Description
Possible Causes
Failure Mode
C028:
GS30,
GS32,
GS46 &
GS47
C028:SERVICE
OVERRIDE MODE ON
Machine is in service override mode.
• Machine programmed for use in service override
mode.
All functions inhibited
except for down
function and up
function.
Platform can be
elevated only once
with the maximum
elevate time of XX
seconds.
Elevate time XX
depends on machine
model.
C029:
GS-3232
C029:SYSTEMFAULT
O/R SENSOR:NOCAL
Outrigger not calibrated.
• Outrigger not calibrated.
• GCON ECM.
All functions operate.
Will not lift above the
down limit switch.
C053:
GS30,
GS32,
GS46 &
GS47
C053:PCON-GCOM
SOFTWARE MISMATCH
Software revisions do not match between the
PCON and GCON.
• Short circuit in the safety switch circuit.
• GCON ECM.
All functions
inhibited.
C055
C055 DCON ECM Fault Type
01
Hardware failur of drive controller
DCON ECM
Performance
reduced or all
functions inhibited.
C056
C056 DCON ECM Fault Type
02
Setup initialization failure of the drive
controller at system startup
• Drive input active at system startup
• Faulty drive joystick
• Incorrect software D14
• DCON ECM
Performance
reduced or all
functions inhibited.
C058
C058 DCON ECM Fault Type
04
Drive controller voltage out of range
• Battery charger connected
• Batteries too low
• DCON ECM
All functions
inhibited.
C059
C059 DCON ECM Fault Type
05
Capacitor charge failure of the drive
controller
• Open on B+ or B- to the drive contoller
• DCON ECM
All functions
inhibited.
C061
C061 DCON ECM Fault Type
07
Open circuit of the key switch circuit or
battery positive / negative of the drive
controller
• Open circuit of the motor controller harness
• Open circuit to the B+ and/or B-
• Key switch relay power not closed
• DCON or GCON ECM
All functions
inhibited.
C063
C063 DCON ECM Fault Type
09
Communication error of the CAN circuit
between the GCON and the motor controller
• Open circuit of the motor controller harness
• DCON or GCON ECM
All functions
inhibited.
C064
C064 DCON ECM Fault Type
10
Output error of the thermal sensor circuit of
the motor controller
DCON ECM
All functions
inhibited.
Note: An error code C053 will be displayed if an updated PCON is installed on a machine that has not had
the GCON updated. The GCOn must be updated, or the original PCON must be installed back on the
machine.
Содержание Genie GS-1530
Страница 205: ...March 2021 Service and Repair Manual Wiring Diagram Ground and Platform Controls Part No 1272217GT GS 30 32 46 47 189 ...
Страница 243: ...March 2021 Service and Repair Manual 227 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 246: ...Service and Repair Manual March 2021 230 Electrical Schematic GS 3232 ANSI CSA from serial number GS3216P 146463 ...
Страница 297: ...March 2021 Service and Repair Manual 281 Electrical Schematic GS 3232 AS CE from serial number GS3216P 146463 ...
Страница 300: ...Service and Repair Manual March 2021 284 Electrical Schematic GS 3232 AS CE from serial number GS3216P 143463 ...
Страница 337: ...March 2021 Service and Repair Manual 321 Electrical Schematic GS 4047 AS CE from serial number GS4716D 3102 ...
Страница 339: ...March 2021 Service and Repair Manual 323 Electrical Schematic Foot Switch option All Models ...