3-5
4.2 Test operation
(1)Turn the power switch on and off a couple times,and check that the pump
rotates in the correct direction.
The correct direction is clockwise,viewed from the motor end of the pump.
If the pump rotates in the reverse direction,change round 2 of the main power
cable's 3 wires.
(2)Turn on the power switch,and run the pump.
・Fix a coupling cover back befare operating the
pump.Hands could get caught up in the coupling.
・Be sure to fix terminal box cover of motor.
There is danger of electric shock.
Do not run the pump in the reverse direction,
or it could break down.
Do not run the pump at closed valve operation for
longer than 5 minutes.If do,the water inside the pump
will heat up,resulting in accident or trouble.
Before operate a pump, flushing the inside of pipe. Any foreign substance in
pump may cause damage on shaft seal or rotation slide part.
Re-start a pump after it stopped totally. Turn the electric power during pump
is running may cause over torque and damage pump.
4 - 2
Содержание SJ4S