Binar-5B/5D-Compact
ENG
Table 6.1 - Malfunction codes
Codes
Malfunction description
Notes / Troubleshooting
01
Overheating
1. Check thoroughly the liquid circuit
2. Check circulation pump, replace if necessary
3. Check temperature sensor and overheating sensor ,replace
if necessary
4. Check the quality of antifreeze to be applied depending on
the ambient temperature
02
Overheating is detected.
Difference between
temperatures measured by
the heat sensor and
overheating sensor is too big.
03
Faulty temperature sensor
№1 on the board sensors
Replace the control unit
04
Faulty temperature sensor
№2 on the board sensors
05
Faulty flame indicator
Check connecting leads. Check ohmic resistance between
indicator contacts, it must be not more 10 Ohm. Replace the
indicator if necessary.
06
Faulty temperature sensor
on the control unit
Replace control unite of the pre-heater
07
Flame failure in low mode
Check air duct, exhaust gas-escape channel and fuel supply,
correct troubles, replace fuel pump and flame indicator if
necessary.
08
Flame failure in full mode
09
Glow plug malfunction
Check the glow plug, replace if necessary.
10
Air pump motor
malfunction
Check the electric wiring of the air pump motor, replace the
air pump, if necessary.
11
Overheating. Heating rate
is too high
1. Check thoroughly the liquid circuit (airlock is possible
before the air pump, cooling liquid cannot be pumped through
the heater)
2. Check cooling liquid for fluidity at low temperatures.
3. Check the pump, replace if necessary
12
Shutdown, voltage boost
16V more
This malfunction is possible if the pre-heater is switched on
when vehicle engine is running. The possible reason of the
trouble is vehicle voltage regulator failure
13
No more tries to start the
pre-heater are left
In case there are no more tries to start the pre-heater left check
fuel supply and amount of fuel supplied. Check the air supply
system to the combustion and exhaust gas-escape channel,
check ignition plug.
14
Pump malfunction
Check circulation pump wiring for short-circuit fault or
disconnection fault. Replace the pump if necessary.
15
Shutdown, low voltage
less then 9.5 V
Check voltage on XS2 connector of the pre-heater. Check the
battery, regulator and power supply wiring.
23
Содержание Binar-5B-Compact
Страница 19: ...Рис 6 25 Схема управления пультом ...
Страница 46: ...Modem GSM TERMINAL car alarm system harness Harness Controlpanel 1 1 i 11 i CD lAtr intake with silencer ...
Страница 56: ...Figure 6 25 The scheme of navigation o n the control panel ...
Страница 74: ...ENG Binar 5B 5D Compact Заметки Notes 36 ...