T5 – Diagnostic & Fault Alarms
High Current Faults
Diagnostic LED Codes
Fault
Description
Indicator
Function
- more than 24A for 10 minutes
- more than 35A for 1 minute
- more than 45A for 30 seconds
- more than 60A for 5 seconds
Disk Heads
- more than 30A for 1 minute
- more than 35A for 2 seconds
Cylindrical Heads
- more than 30A for 1 minute
- more than 35A for 2 seconds
Disk Heads
- more than 30A for 1 minute
- more than 35A for 2 seconds
Cylindrical Heads
- more than 30A for 1 minute
- more than 35A for 2 seconds
- more than 27A for 30 seconds
- more than 30A for 5 seconds
Excessive Right Brush
Motor current
Turns OFF all Scrub functions
Excessive Vacuum Fan
Motor current
Turns OFF all Scrub functions
Fault LED #
3
and Lower Brush
Pressure (#
1
) LED flashing
Fault LED #
2
flashing
Excessive Propel current
Prevents movement of the machine;
Turn Key Switch OFF/ON to propel
for another time period.
Excessive Left Brush
Motor current
Turns OFF all Scrub functions
Fault LED's #
2
and #
3
flashing
Fault LED #
1
and Lower Brush
Pressure (#
1
) LED flashing
Fault
Entry Sequence
Indicator
Function
Possible Solutions
High Throttle
Disable
Key switch turned ON with
propel engaged
Battery Gauge LED's
continuously "ripple"
UP and Down
Prevents movement of machine if
propel is engaged before key is
switched ON
Release propel bail before turning Key
Switch ON; Adjust Throttle Position Sensor
neutral voltage (2.4v to 2.6v)
Charger
Connected
Battery charger connected to
machine and/or AC power
with Key Switch ON
Fault LED's
continuously "ripple"
UP and DOWN
Prevents operation of the machine
with charger plugged in
Plug in Battery Charger only when
machine is not in use
Throttle
Controller sensed an out-of
range Throttle signal
Fault LED's #
1
and
#
2
flashing
Prevents movement of machine
with invalid throttle voltage. Scrub
function shuts off.
Repair throttle wiring; Repair or replace
machine Control Board
Recovery Tank
Controller sensed an open
circuit - Recovery Tank is
raised
Fault LED #
1
flashing
Prevents movement of the
machine when Recovery Tank is
raised
Lower Recovery Tank when operating
machine
Emergency Stop
Switch
Controller sensed an open
circuit - Emergency Stop
Switch activated
All Battery Gauge
LED's flashing
Turns OFF all machine functions
Reset Emergency Stop Switch
Scrub Head
Actuator Motor
Scrub Head Actuator motor
stalled or actuator position
unknown
Fault LED's #
1
and
#
3
flashing
Notify operator of actuator fault
Examine Scrub Head Actuator or linkage
for binding; Repair or replace Scrub Head
Actuator
FaST Pump
FaST Pump circuit OPEN or
SHORTED
Fault LED #
3
flashing
Notify operator of FaST Pump
fault
Repair FaST Pump wiring; Repair or
replace FaST Pump
Wand Pump
Wand Pump circuit OPEN or
SHORTED
Fault LED's #
1
,
#
2
and #
3
flashing
Notify operator of Wand Pump
fault
Repair Wand Pump wiring; Repair or
replace Wand Pump
High Current
Controller sensed an Over
Current condition in a motor
Various LED's flashing
Prevent damage to motors; Refer
to appropriate chart for more
information
Repair motor wiring; Repair or replace
motor
50
T5 9002333 REV.0
2
(07-06)
E
Содержание T5
Страница 28: ...T5 Wiring Harness Detail Page 1 of 6 24 T5 9002333 REV 02 11 07 A CONTINUED B CONTINUED Symbol Key E ...
Страница 29: ...T5 Wiring Harness Detail Page 2 of 6 T5 9002333 REV 02 11 07 25 B Symbol Key E ...
Страница 30: ...T5 Wiring Harness Detail Page 3 of 6 26 T5 9002333 REV 02 11 07 A C CONTINUED Symbol Key E ...
Страница 31: ...T5 Wiring Harness Detail Page 4 of 6 T5 9002333 REV 02 11 07 27 C Symbol Key E ...
Страница 32: ...T5 Wiring Harness Detail Page 5 of 6 Symbol Key 28 T5 9002333 REV 02 11 07 E ...
Страница 33: ...T5 Wiring Harness Detail Page 6 of 6 Symbol Key T5 9002333 REV 02 11 07 29 E ...