OPERATION
7100 330690 (9--09)
18
CIRCUIT BREAKERS
Circuit breakers
are resetable electrical circuit
protection devices designed to stop the flow of
current in the event of a circuit overload. Once a
circuit breaker
is tripped, reset it manually by
pressing the reset button after the breaker has
cooled down.
If the overload that caused the
circuit breaker
to
trip is still present, the
circuit breaker
will continue
to stop current flow until the problem is corrected.
The
circuit breakers
are located on the operator
console.
The chart below shows the
circuit breakers
and
the electrical components they protect.
Circuit
Breaker
Rating
Circuit Protected
CB1
2.5 A
Machine power
CB2
2.5 A
Lights
CB3
10 A
Horn
CB4
10 A
Power wand/
Back up alarm
CB5
10 A
Control panel
CB6
20 A
Vacuum Fan (single)
CB6
40 A
Vacuum Fan (dual)
CB7
10 A
ES System (option)
FaST System (option)
CB8
25 A
Left brush motor
CB9
25 A
Right brush motor
CB10
2.5 A
ec--H20 (option)
CB11
2.5 A
ec--H20 (option)
FUSE
The
fuse
is a one-time protection device designed
to stop the flow of current in the event of a circuit
overload.
NOTE: Always replace the fuse with a fuse of the
same amperage.
The
fuse
is located behind the operator console.
Access the
fuse
by lowering the operator console.
Fuse
Rating
Circuit Protected
FU-1
40 A
Propelling