MAINTENANCE
7100 330690 (6--02)
76
6. Position the brush with the
double row end
towards you.
Guide the new brush onto the
drive hub.
7. Insert the Idler plug (on the inside of the idler
door), into the brush.
8. Push down on the door to catch the door in
the scrub head, then pull up on the door to
latch it into the spring.
9. Repeat for the other brush on the other side
of the scrub head.
NOTE: Each side of the scrub head is stamped
with a letter. The idler door of that side of the
scrub head is stamped with the same letter. Make
sure the letter on the door matches the letter on
the scrub head when replacing the doors.
SOLUTION SYSTEM
RECOVERY TANK
The recovery tank holds recovered solution. Clean
and drain the recovery tank after each use. The
outside of the tank can be cleaned with vinyl
cleaner.
ES mode: Flush out the recovery tank with clean
water after each use.
NOTE:
DO NOT
use steam to clean the tanks.
Excessive heat can damage the tanks and
components.
Thoroughly rinse the pressure switches inside the
recovery tank after each use.