MAINTENANCE
186E MM160 (6–94)
3Ć10
TO CHARGE BATTERIES (For machines serial
number 006823 and above)
1. Stop the machine on a flat, dry surface next
to an electrical outlet.
2. Turn the on-off switch to the left.
3. Remove the access covers.
WARNING: Batteries Emit Hydrogen
Gas. Explosion Or Fire Can Result.
Keep Sparks And Open Flame Away. Keep
Covers Open When Charging.
4. Check the electrolyte level in the batteries.
Before charging, add just enough distilled
water to cover the plates. Then, after
charging is completed, add enough water to
bring the electrolyte up to the indicator mark.
If the water level is topped off before
charging, normal expansion of the
electrolyte may cause an overflow, resulting
in loss of acid balance and acid damage to
the machine area around the batteries.
FOR SAFETY: When Servicing Machine, Avoid
Contact With Battery Acid.
5. Plug the battery charger into an AC wall
outlet. The charger will go through a self
diagnostic check. All the indicator lamps on
the charger panel will flash showing the
diagnostic check is in progress.
A
B
C
D
E
F
06898
CHARGER PANEL
A. Interrupt Switch
B. Red No Charge Indicator Lamp
C. Yellow Charger On Indicator Lamp
D. Red Incomplete Battery Status
Indicator Lamp
E. Yellow 80% Charge Indicator Lamp
F. Green Complete Charge Indicator
Lamp
NOTE: If the “red no charge indicator lamp” lights
when the charger is plugged into a wall outlet, the
charger can not charge the battery, meaning there
is something wrong with the battery.
When the lamps stop flashing, the “red
incomplete battery status indicator lamp”
lights. After a short delay, the “yellow
charger on indicator lamp” lights showing the
charger has turned on.
As the battery charges, the “red incomplete
battery status indicator lamp” goes out and
the “yellow 80% charge indicator lamp”
lights.
Finally the “yellow 80% charge indicator
lamp” goes out and the green complete
charge indicator lamp lights showing the
battery is completely charged. After a short
time, the “yellow charger on indicator lamp”
goes out showing the charger has turned off.
The “green complete charge indicator lamp”
will remain on until the charger is unplugged
from the wall outlet.
NOTE: If the charge cycle has to be stopped,
press the interrupt switch while unplugging the
charger from the wall outlet.
6. Unplug the charger from the wall outlet.
7. Check the batteries electrolyte level; it
should be up to the indicator mark.
A
B
00879
CHECKING BATTERY ELECTROLYTE LEVEL
A. Battery
B. Electrolyte Indicator Ring
8. Replace the access covers.
Содержание 186E
Страница 1: ...186E MM160 Rev 12 12 95 Operator Manual ...
Страница 8: ...GENERAL INFORMATION 186E MM160 6 94 vi ...
Страница 10: ...SPECIFICATIONS 186E MM160 6 94 1Ć2 ...
Страница 14: ...OPERATION 186E MM160 6 94 2Ć2 ...
Страница 48: ...MAINTENANCE 186E MM160 6 94 3Ć12 ELECTRICAL SCHEMATIC 186E For machines below serial number 004369 03130 ...
Страница 49: ...MAINTENANCE 3Ć13 186E MM160 6 94 ELECTRICAL SCHEMATIC 186E For machines serial number 004369 to 006822 03130 ...
Страница 50: ...MAINTENANCE 186E MM160 6 94 3Ć14 ELECTRICAL SCHEMATIC 186E For machines serial number 006823 and above 03130 ...
Страница 51: ...MAINTENANCE 3Ć15 186E MM160 6 94 ELECTRICAL SCHEMATIC 186EE For machines below serial number 006823 03095 ...
Страница 52: ...MAINTENANCE 186E MM160 6 94 3Ć16 ELECTRICAL SCHEMATIC 186EE For machines serial number 006823 and above 03095 ...
Страница 84: ...APPENDIX 186E MM160 6 94 4Ć2 ...
Страница 86: ...APPENDIX 186E MM160 6 94 4Ć4 ...