MAINTENANCE
186E MM160 (6–94)
3Ć8
ELECTRICAL SYSTEM
BATTERIES
The two 12-volt machine batteries provide all of
the energy used by the machine. The batteries
are rated at 140 Amp/hours at a 20-hour rate.
They require regular maintenance to keep them
operating their best.
Do not allow batteries to remain in discharged
condition for any length of time.
Do not operate machine if batteries are in poor
condition or only 25% of the charge is left.
Periodically check the battery cables for loose
connections and corrosion.
Clean the top surface and the terminals of the
batteries after every 100 hours of operation. Use
a strong solution of baking soda and water. Brush
the solution sparingly over the battery top,
terminals, and cable clamps. Do not allow any
baking soda solution to enter the battery. Use a
wire brush to clean the terminal posts and the
cable connectors. After cleaning, apply a coating
of clear petroleum jelly to the terminals and the
cable connectors. Keep the tops of the batteries
clean and dry.
Keep all metallic objects off the top of the
batteries, as they may cause a short circuit.
Replace worn or damaged wires.
Check the electrolyte level in each battery cell
after every 25 hours of operation. The electrolyte
level must always be above the battery plates.
Add distilled water to maintain solution at the
correct level above the plates, but do not overfill.
Never add acid to batteries, only water. Keep vent
plugs firmly in place at all times, except when
adding water or taking hydrometer readings.
FOR SAFETY: When Servicing Machine, Avoid
Contact With Battery Acid.
Use a hydrometer to check the electrolyte specific
gravity.
A
B
01373
CHECKING BATTERY SPECIFIC GRAVITY
A. Hydrometer
B. Battery
If one or more battery cells tests lower than the
other battery cells, (0.050 or more) the cell is
damaged, shorted, or is about to fail.
NOTE: Do not take readings immediately after
adding water––if the water and acid are not
thoroughly mixed, the readings may not be
accurate. Check the hydrometer readings against
this chart:
SPECIFIC GRAVITY
BATTERY
at 80
F (27
C)
CONDITION
1.265
100% charged
. . . . . . . . . . . . . . . . . . . . . . . . .
1.225
75% charged
. . . . . . . . . . . . . . . . . . . . . . . . . .
1.190
50% charged
. . . . . . . . . . . . . . . . . . . . . . . . . .
1.155
25% charged
. . . . . . . . . . . . . . . . . . . . . . . . . .
1.120
Discharged
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 80
F
(27
C), the reading must be temperature
corrected.
To determine the corrected specific gravity
reading when the temperature of the battery
electrolyte is other than 80
F (27
C):
Add to the specific gravity reading 0.004,
4 points, for each 10
F (6
C) above 80
F
(27
C).
Subtract from the specific gravity reading
0.004, 4 points, for each 10
F (6
C) below
80
F (27
C).
Содержание 186E
Страница 1: ...186E MM160 Rev 12 12 95 Operator Manual ...
Страница 8: ...GENERAL INFORMATION 186E MM160 6 94 vi ...
Страница 10: ...SPECIFICATIONS 186E MM160 6 94 1Ć2 ...
Страница 14: ...OPERATION 186E MM160 6 94 2Ć2 ...
Страница 48: ...MAINTENANCE 186E MM160 6 94 3Ć12 ELECTRICAL SCHEMATIC 186E For machines below serial number 004369 03130 ...
Страница 49: ...MAINTENANCE 3Ć13 186E MM160 6 94 ELECTRICAL SCHEMATIC 186E For machines serial number 004369 to 006822 03130 ...
Страница 50: ...MAINTENANCE 186E MM160 6 94 3Ć14 ELECTRICAL SCHEMATIC 186E For machines serial number 006823 and above 03130 ...
Страница 51: ...MAINTENANCE 3Ć15 186E MM160 6 94 ELECTRICAL SCHEMATIC 186EE For machines below serial number 006823 03095 ...
Страница 52: ...MAINTENANCE 186E MM160 6 94 3Ć16 ELECTRICAL SCHEMATIC 186EE For machines serial number 006823 and above 03095 ...
Страница 84: ...APPENDIX 186E MM160 6 94 4Ć2 ...
Страница 86: ...APPENDIX 186E MM160 6 94 4Ć4 ...