OPERATION
186 MM159 (6–94)
2Ć14
TO SCRUB
Plan the scrubbing in advance. Try to arrange
long runs with minimum stopping and starting. Do
an entire floor or section at one time.
Pick up oversize debris before scrubbing.
Remove bulky debris from aisles before
scrubbing. Pick up pieces of wire, twine, string,
etc., which could become entangled in brush or
brush plugs.
Allow a few inches overlap of brush paths.
Try to scrub as straight a path as possible. Avoid
bumping into posts or scraping the sides of the
machine.
Floor conditions, amount of soilage, type of
soilage, brush action, and squeegee action all
play an important role in determining the type and
concentration of detergent to be used. For
specific recommendations, consult the local
Tennant Company Representative.
WARNING: Flammable Materials Can
Cause An Explosion Or Fire. Do Not
Use Flammable Materials In Tank(s).
The recovery tank should be drained after the
solution tank is empty and whenever the float
rises and stops water vacuum. The recovery tank
may fill before the solution tank empties if
standing water is picked up in addition to the
solution put down by the machine.
For best scrubbing results, reduce speed to
one-half maximum machine speed. Shut off
solution flow to floor 5 ft (1.5 m) before making
turns. Always raise the rear squeegee before
backing machine. Adjust solution flow to floor with
solution flow control lever to match floor
conditions.
1. Stop the engine before filling solution tanks.
FOR SAFETY: Before Leaving Or Servicing
Machine; Stop On Level Surface, Set Parking
Brake, And Turn Off Machine.
NOTE: For machines serial number 004369 and
above, the filter shaker by-pass switch should be
in the “off” position to prevent the filter shaker
from shaking.
2. Open the solution tank cover.
A
B
C
03150
SOLUTION TANK COVER
A. Solution Tank
B. Cover
C. Soap Basket
3. Pour the required amount of detergent into
the soap basket. Fill the tank with water to
1 in (25 mm) above the top of the screened
portion of the soap basket.
NOTE: The water must not be hotter than 130
F
(54
C) or tank damage may occur.
4. Start and drive the machine to the area to
be scrubbed.
5. Move the main brush lever into the (Main
Brush Down) or (Main Brush Free-Float)
position.
6. Move the side brush arm into the down
position.
7. Place the solution spreader tube in the down
position.
8. Move the solution lever into the on position.
9. Lower the squeegee lever into the down
position.
Содержание 186
Страница 1: ...186 MM159 Rev 05 12 95 Operator Manual ...
Страница 10: ...SPECIFICATIONS 186 MM159 6 94 1Ć2 ...
Страница 14: ...OPERATION 186 MM159 6 94 2Ć2 ...
Страница 52: ...MAINTENANCE 186 MM159 6 94 3Ć16 ELECTRICAL SCHEMATIC For machines below serial number 003181 03145 ...
Страница 53: ...MAINTENANCE 3Ć17 186 MM159 6 94 ELECTRICAL SCHEMATIC For machines serial number 003181 to 004368 03145 ...
Страница 54: ...MAINTENANCE 186 MM159 6 94 3Ć18 ELECTRICAL SCHEMATIC For machines serial number 004369 and above 03145 ...
Страница 84: ...MAINTENANCE 186 MM159 6 94 3Ć48 ...
Страница 86: ...APPENDIX 186 MM159 6 94 4Ć2 ...
Страница 88: ...APPENDIX 186 MM159 6 94 4Ć4 ...