background image

INSTALLATION INSTRUCTIONS

Gas Furnace: (F/G)9MAE

440 01 4300 02

31

Specifications subject to change without notice.

3. Secure BX cable to J

Box bracket with connectors

approved for the type of cable used.

4. Connect field ground wire and factory ground wire to

green ground screw on J

Box mounting bracket as

shown in 

Figure 36

.

5. Connect field power and neutral leads to furnace power

leads. as shown in 

Figure 34

.

6. Attach furnace J

Box cover to mounting bracket with

screws supplied in loose parts bag. Do not pinch wires

between cover and bracket.

24

V Wiring

Make field 24

v connections at the 24

v terminal strip. (See

Figure 39

) Connect terminal Y/Y2 as shown in 

Figure 34

 for

proper cooling operation. Use only AWG No. 18, color

coded,

copper thermostat wire.

NOTE

:  Use AWG No. 18 color-coded copper thermostat wire

for lengths up to 100 ft. (30.5 M). For wire lengths over 100 ft.,
use AWG No. 16 wire.
The 24

v circuit contains an automotive

type, 3

amp. fuse

located on the control. Any direct shorts during installation,

service, or maintenance could cause this fuse to blow. If fuse

replacement is required, use ONLY a 3

amp. fuse of identical

size. (See  

Figure 38 

and 

Figure 39

)

See the Service and Technical Support manual for detailed

instructions on control wiring and setup.

Thermostats and Control Settings

For best results, use a communicating wall control to control

this modulating furnace. A single stage or two

stage heating

and cooling thermostat can be used with the furnace. The

furnace control board CPU will control the furnace and outdoor

unit staging. A two stage heating and cooling thermostat can

also be used to control the staging. However, full modulating

capability will not be available when the furnace staging is

controlled by the thermostat. Furnace staging will be limited to

Minimum and Maximum inputs or Intermediate and Maximum

inputs depending on the configuration of set-up switches

SW1-2 and SW4-2. Refer to typical thermostat wiring diagrams

and the Sequence of Operation section for additional details.

Consult the thermostat installation instructions for specific

information about configuring the thermostat.

Accessories 

(

See 

Figure 38 

and

 Figure 39)

1. Electronic Air Cleaner (EAC)

Connect an accessory Electronic Air Cleaner (if used)

using 1/4

in female quick connect terminals to the two

male 1/4

in quick

connect terminals on the control

board marked EAC

1 and EAC

2. The terminals are

rated for 115VAC, 1.0 amps maximum and are

energized during blower motor operation.

2. Humidifier (HUM)

The HUM terminal is a 24 VAC output, energized

when the blower is operating during a call for heat.
Connect an accessory 24 VAC, 0.5 amp. Maximum (if

used) to the 1/4

in male quick

connect HUM terminal

and COM

24V screw terminal on the control board

thermostat strip.

NOTE

:  If the humidifier has its own 24 VAC power supply, an

isolation relay may be required. Connect the 24 VAC coil of the
isolation relay to the HUM and COM/24V screw terminal on the

control board thermostat strip. (See 

Figure 39

)

3. Communication Connector

This connection is used when the furnace is

controlled by an optional communicating wall control

instead of a standard thermostat. The communication

plug is supplied with the communicating wall control.

Refer to the instructions supplied with the

communicating wall control for complete details.

4. Outside Air Thermistor (OAT)

The OAT connection is used in conjunction with

communicating wall control. It is not required when the

furnace is controlled by a standard type thermostat.

Refer to the instructions supplied with the

communicating wall control for complete details.

Alternate Power Supplies

This furnace is designed to operate on a utility generated

power which has a smooth sinusoidal waveform. If the furnace

is to be operated on a generator or other alternate power

supply, the alternate power supply must produce a smooth

sinusoidal waveform for compatibility with furnace electronics.

The alternate power supply must generate the same voltage,

phase, and frequency (Hz) as shown in 

Table 11

 or on the

furnace rating plate.
Power from an alternate power supply that non-sinusoidal may

damage the furnace or cause erratic furnace operation.
Contact the alternate power supply manufacturer for

specifications and details.

Table 11

Electrical Data 

 MODULATING (F/G)9MAE

UNIT SIZE

VOLTS

HERTZ

PHASE

OPERATING VOLTAGE

RANGE*

MAXIMUM

UNIT

AMPS

UNIT

AMPACITY#

MINIMUM

WIRE

SIZE

AWG

MAXIMUM

WIRE

LENGTH

FT (M)

}

MAXIMUM

FUSE OR

CKT BKR

AMPS

{

Maximum*

Minimum*

0601714

115-60-1

127

104

9.7

12.7

14

29 (8.8)

15

0602120

115-60-1

127

104

14.8

19.1

12

30 (9.1)

20

0801714

115-60-1

127

104

9.7

12.7

14

29 (8.8)

15

0802120

115-60-1

127

104

14.8

19.1

12

30 (9.1)

20

1002122

115-60-1

127

104

14.8

19.1

12

30 (9.1)

20

1202422

115-60-1

127

104

14.8

19.1

12

30 (9.1)

20

* Permissible limits of the voltage range at which the unit operates satisfactorily.
# Unit ampacity = 125 percent of largest operating component’s full load amps plus 100 percent of all other potential operating components’ (EAC, humidifier,  etc.) full load

amps.

 Time

delay type is recommended.

 Length shown is as measured one way along wire path between unit and service panel for maximum 2 percent voltage drop.

Содержание F9MAE

Страница 1: ...owing manner Safety alert symbol When you see this symbol on the unit and in instructions or manuals be alert to the potential for personal injury TABLE OF CONTENTS SAFETY CONSIDERATIONS 3 INTRODUCTION 4 CODES AND STANDARDS 4 ELECTROSTATIC DISCHARGE PRECAUTIONS PROCEDURE 5 DIMENSIONS 6 LOCATION 7 LOCATION RELATIVE TO COOLING EQUIPMENT 8 AIR FOR COMBUSTION AND VENTILATION 9 CONDENSATE TRAP 10 INSTA...

Страница 2: ... grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state of local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless u...

Страница 3: ... clothing and work gloves Have a fire extinguisher available Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit CAUTION CUT HAZARD Failure to follow this caution may result in personal injury Sheet metal parts may have sharp edges or burrs Use care and wear appropriate protective clothing safety glasses and gloves when handling pa...

Страница 4: ...n in mobile homes recreational vehicles or outdoors This furnace is designed for minimum continuous return air temperature of 60 F 15 C db or intermittent operation down to 55 F 15 C db such as when used with a night setback thermostat Return air temperature must not exceed 80 F 27 C db Failure to follow these return air temperature limits may affect reliability of heat exchangers motors and contr...

Страница 5: ...ocedure These precautions will help to avoid exposing the control to electrostatic discharge by putting the furnace the control and the person at the same electrostatic potential 1 Disconnect all power to the furnace Multiple disconnects may be required DO NOT TOUCH THE CONTROL OR ANY WIRE CONNECTED TO THE CONTROL PRIOR TO DISCHARGING YOUR BODY S ELECTROSTATIC CHARGE TO GROUND 2 Firmly touch the c...

Страница 6: ... KG CABINET WIDTH OUTLET WIDTH BOTTOM INLET WIDTH AIR INTAKE 0601714 17 1 2 445 15 7 8 403 16 406 8 3 4 222 154 69 0602120 21 533 19 3 8 492 19 1 2 495 10 1 2 267 159 72 0801714 17 1 2 445 15 7 8 403 16 406 8 3 4 222 164 74 0802120 21 533 19 3 8 492 19 1 2 495 10 1 2 267 169 77 1002122 21 533 19 3 8 492 19 1 2 495 10 1 2 267 179 80 1202422 24 1 2 622 22 7 8 581 23 584 12 1 4 311 203 91 ...

Страница 7: ...e shipped in the main blower compartment See Table 2 for loose parts bag contents This furnace must be installed so the electrical components are protected from water not be installed directly on any combustible material other than wood flooring refer to SAFETY CONSIDERATIONS be located close to the chimney or vent and attached to an air distribution system Refer to Air Ducts section be provided a...

Страница 8: ...e airplane hangar or other building having a hazardous atmosphere the furnace must be installed in accordance with the NFPA 54 ANSI Z223 1 2012 or CAN CSA B149 1 2010 See Figure 4 Figure 4 Installation in a Garage A93044 WARNING FIRE HAZARD Failure to follow this warning could result in personal injury death and or property damage Do not install the furnace on its back or hang furnace with control...

Страница 9: ...orten furnace life Air contaminants are found in aerosol sprays detergents bleaches cleaning solvents salts air fresheners and other household products WARNING CARBON MONOXIDE POISONING HAZARD Failure to follow this warning could result in personal injury or death The operation of exhaust fans kitchen ventilation fans clothes dryers attic exhaust fans or fireplaces could create a NEGATIVE PRESSURE...

Страница 10: ...00 237 8 10 500 297 3 8 400 237 8 9 000 254 6 12 000 339 5 15 000 424 4 18 000 509 2 21 000 594 1 0 00 NP NP NP NP NP NP NP NP NP NP Not Permitted CONDENSATE TRAP CAUTION FROZEN AND BURST WATER PIPE HAZARD Failure to protect against the risk of freezing may result in property damage Special precautions MUST be made if installing furnace in an area which may drop below freezing This can cause impro...

Страница 11: ...nd after relocation Refer to Figure 8 to begin the trap conversion Refer to Condensate Drain section for information how to install the condensate drain Figure 7 Upflow Trap Configuration Condensate Trap Relief Port Collector Box Plugs Pressure Switch Port Condensate Trap Outlet Condensate Trap Relief Port Collector Box Plug Vent Elbow Vent Elbow Clamp Vent Pipe Clamp A11306 Representative drawing...

Страница 12: ...he condensate trap See Figure 16 NOTICE The field supplied accessory horizontal drain trap grommet is ONLY REQUIRED FOR DIRECT VENT APPLICATIONS It is NOT required for applications using single pipe or ventil ated combustion air venting NOTICE The condensate trap extends below the side of the casing in the horizontal position A minimum of 2 in 51 mm of clear ance is required between the casing sid...

Страница 13: ...ight plug from collector box DO NOT DISCARD Remove relief tube from port on collector box A11586A Figure 9 continued Horizontal Left Trap Configuration A11586B Representative drawing only some models may vary in appearance Rotate elbow to desired position and torque clamp on inlet 15 lb in Slide relief tube in stand offs to adjust length Attach condensate trap to collector box with screw Align tra...

Страница 14: ...N FROZEN AND BURST WATER PIPE HAZARD Failure to protect against the risk of freezing may result in property damage Special precautions MUST be made if installing furnace in an area which may drop below freezing This can cause improper operation or damage to equipment If furnace environment has the potential of freezing the drain trap and drain line must be protected The use of accessory drain trap...

Страница 15: ...be constructed from field supplied 1 2 in CPVC or 3 4 in PVC pipe in compliance with local building codes A factory supplied 1 2 in CPVC to 3 4 in PVC adapter is supplied in the loose parts bag for use as required 7 Install the adapter or connect the 1 2 in CPVC pipe by sliding a spring clamp over the open end of the grommet on the outside of the furnace casing 8 Open the spring clamp and insert t...

Страница 16: ...nd shocks to the drain line from damaging the furnace drain trap Avoid misalignment of the drain pipe which may cause kinks in the elbow Horizontal Orientation 1 The condensate trap outlet extends 2 in 51 mm below the furnace casing Leave enough clearance between the furnace and the furnace platform for the trap 2 To allow for servicing the trap the condensate drain elbow in the loose parts bag ca...

Страница 17: ... This furnace is certified to leak 2 or less of nominal air con ditioning CFM delivered when pressurized to 1 inch water column 250 Pa with all present air inlets including bottom closure in upflow and horizontal applications air outlets and plumbing and electrical ports sealed UPFLOW INSTALLATION NOTE The furnace must be pitched as shown in Figure 17 for proper condensate drainage Figure 17 Furna...

Страница 18: ...ns Do not use side return air openings in DOWNFLOW configuration See Figure 26 Figure 27 and Figure 28 Leveling Legs If Desired In upflow position with side return inlet s leveling legs may be used See Figure 19 Install field supplied 5 16 x 1 1 2 in 8 x 38 mm max corrosion resistant machine bolts washers and nuts Figure 19 Leveling Legs A89014 NOTE Bottom closure must be used when leveling legs a...

Страница 19: ...ory subbase or a factory approved air conditioning coil casing DO NOT cut main furnace casing to attach supply side air duct humidifier or other accessories All supply side accessories MUST be connected to duct external to furnace casing Return Air Connections WARNING FIRE HAZARD A failure to follow this warning could cause personal injury death and or property damage Never connect return air duct...

Страница 20: ...se not required 23 584 21 1 8 537 23 5 8 600 22 1 4 565 Downflow Applications on Noncombustible Flooring subbase not required 22 7 8 581 19 483 23 1 2 597 19 5 8 498 Downflow applications on Combustible flooring subbase required 22 1 8 562 19 483 23 3 4 603 20 5 8 600 Downflow Applications on Combustible Flooring with Coil Assembly or coil box subbase not required 22 1 2 572 19 483 23 1 2 597 20 5...

Страница 21: ...e may be supported under the entire length of the furnace with threaded rod and angle iron See Figure 24 Secure angle iron to bottom of furnace as shown Platform Furnace Support Construct working platform at location where all required furnace clearances are met See Table 1 and Figure 25 For furnaces with 1 in 25 mm clearance requirement on side set furnace on non combustible blocks bricks or angl...

Страница 22: ... cover attachment shall prevent leaks Connect supply air duct to flanges on furnace supply air outlet Bend flange upward to 90 with wide duct pliers See Figure 21 The supply air duct must be connected to ONLY the furnace supply outlet air duct flanges or air conditioning coil casing when used DO NOT cut main furnace casing side to attach supply air duct humidifier or other accessories All supply s...

Страница 23: ...25 x 3 4 610 x 635 x 19 Washable Recommended to maintain air filter face velocity See Product Data for part number Refer to the instructions supplied with the Filter Rack or accessory air filter for additional assembly and installation options Filter and Return Duct Sizing Pressure drop must be taken into account when sizing filters filter racks IAQ devices and associated system ductwork See Table...

Страница 24: ...ashable Representative After Market Filter Media Fiberglass Pleated CFM L s 1 in 2 5 cm 1 in 2 5 cm 2 in 5 cm 1 in 2 5 cm 2 in 5 cm 800 378 0 03 9 0 05 12 0 07 18 0 17 43 0 11 28 1000 472 0 04 11 0 06 16 0 09 24 0 22 55 0 15 37 1200 566 0 05 13 0 08 20 0 12 31 0 27 68 0 18 47 1400 661 0 06 15 0 10 24 0 15 38 0 23 58 1600 755 0 06 16 0 11 29 0 18 45 0 28 69 1800 850 0 07 18 0 13 34 0 21 53 2000 944...

Страница 25: ...ons L10F032 Figure 28 Horizontal Return Air Configurations and Restrictions HORIZONTAL TOP RETURN NOT PERMITTED FOR ANY MODEL SIDE RETURN AIR NOT PERMITTED FOR 2000 CFM AND ABOVE OF AIR FLOW L10F034 External Filter Cabinet Configurations Figure 29 Accessory Side Filter Rack TABS FILTER FRAME FILTER DOOR FURNACE L10F027 OPENING TABS TYP OPENING 11 4 23 59 cm 25 64 cm 1 cm 1 3 cm 2 6 cm 17 43 5 cm 2...

Страница 26: ...turn air shall also be handled by duct s sealed to the furnace casing and terminating outside the space containing the furnace Secure ductwork with proper fasteners for type of ductwork used Seal supply and return duct connections to furnace with code approved tape or duct sealer NOTE Flexible connections should be used between ductwork and furnace to prevent transmission of vibration Ductwork pas...

Страница 27: ...o Table 10 for recommended gas pipe sizing Risers must be used to connect to furnace and to meter Support all gas piping with appropriate straps hangers etc Use a minimum of one hanger every 6 ft 1 8 M Joint compound pipe dope should be applied sparingly and only to male threads of joints Pipe dope must be resistant to the action of propane gas WARNING FIRE OR EXPLOSION HAZARD A failure to follow ...

Страница 28: ...ockout for the gas pipe must be sealed to prevent air leakage Remove the knockout install the grommet in the knockout then insert the gas pipe The grommet is included in the loose parts bag See Figure 33 Figure 33 Gas Entry Gas Pipe Grommet Required For Direct Vent Applications Left Side Gas Entry Gas Pipe Grommet Required For Direct Vent Applications A11338 ELECTRICAL CONNECTIONS ELECTRICAL SHOCK...

Страница 29: ...uit breaker for this furnace See Table 11 for wire size and fuse specifications A readily accessible means of electrical disconnect must be located within sight of the furnace J Box Installation WARNING FIRE OR ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personal injury death or property damage If field supplied manual disconnect switch is to be mounted on furnace casing...

Страница 30: ...g bracket as shown in Figure 36 7 Connect field power and neutral leads to furnace power leads as shown in Figure 34 8 Attach furnace J Box cover to mounting bracket with screws supplied in loose parts bag Do not pinch wires between cover and bracket 9 Complete external disconnect wiring and installation Connect line voltage leads as shown in Figure 37 Use best practices NEC ANSI NFPA 70 in U S fo...

Страница 31: ...ration 2 Humidifier HUM The HUM terminal is a 24 VAC output energized when the blower is operating during a call for heat Connect an accessory 24 VAC 0 5 amp Maximum if used to the 1 4 in male quick connect HUM terminal and COM 24V screw terminal on the control board thermostat strip NOTE If the humidifier has its own 24 VAC power supply an isolation relay may be required Connect the 24 VAC coil o...

Страница 32: ...midifiers with Internal Power Supply 24 V Coil To Humidifier Leads To Com 24V Screw Terminal on Thermostat Strip To HUM 24 VAC Terminal On Furnace Control Board To Humidifier Leads A11157 Figure 39 Variable Speed Furnace Control Switch Locations OAT PL9 PL4 PL7 SW 1 SW2 SW3 SW4 O N W2 Y1 DHUM 8 7 6 5 4 3 2 1 3 2 1 O N O N O N 3 2 1 3 2 1 L11F080 ...

Страница 33: ...e special vent fittings accessory concentric vent termination kits and accessory external drain trap available from the furnace manufacturer have been certified to ULC S636 for use with those Royal Pipe and IPEX PVC vent components which have been certified to this standard In Canada the primer and cement must be of the same manufacturer as the vent system GVS 65 Primer Purple for Royal Pipe or IP...

Страница 34: ...illage from draft hood equipped appliances at the draft hood relief opening after 5 minutes of main burner operation Use the flame of a match or candle 8 If improper venting is observed during any of the above tests the venting system must be corrected in accordance with the National Fuel Gas Code ANSI Z223 1 NFPA 54 and or CSA B149 1 Natural Gas and Propane Installation Code 9 After it has been d...

Страница 35: ...tmospheric pressure zone either through the roof preferred or a sidewall See Figure 58 for references to clearances required by National code authorities NOTICE Optional Configuration for Combustion Air Inlet Pipe In applications where there is a risk of excessive moisture entering the combustion air inlet pipe a moisture trap may be added to the inlet pipe to help prevent moisture from entering t...

Страница 36: ...ER PRIME AND CEMENT VENT PIPE TO ADAPTER ALLOW TO DRY BEFORE IN STALLING VENT COUPLING A13076A Figure 42 Vent Pipe Flush Showing Coupling ALIGN NOTCHES IN VENT PIPE COUPLING OVER STAND OFF ON ADAPTER TORQUE LOWER CLAMP 15 LB IN WHEN REMAINING VENT PIPE IS INSTALLED TORQUE UPPER CLAMP TO 15 LB IN A13076B Locating the Vent Termination General NOTE Termination Requirements for the Provinces of Albert...

Страница 37: ...8 of CAN CSA B149 1 10 Venting Systems and Air Supply for Appliances and all authorities having jurisdiction Ventilated Combustion Air The vent pipe for a Ventilated Combustion Air System must terminate outdoors See Figure 58 for references to vent clearances required by National code authorities Allowable vent terminations are shown in Figure 47 The combustion air pipe terminates in a well ventil...

Страница 38: ... 44 Sample Inlet Air Pipe Connection for Polypropylene Venting Systems EXAMPLE FOR UPFLOW INSTALLATIONS MAY BE APPLIED TO OTHER CONFIGURATIONS A12220 Figure 45 Vent Terminations 12 IN 305 MM MIN SEPARATION BETWEEN BOTTOM OF COMBUSTION AIR AND BOTTOM OF VENT MAINTAIN 12 IN 305 MM CLEARANCE ABOVE HIGHEST ANTICIPATED SNOW LEVEL OR GRADE WHICHEVER IS GREATER COMBUSTION AIR ELBOW PARALLEL TO WALL OPTIO...

Страница 39: ...ow level or grade whichever is greater Typ At least 36 in 914mm At least 36 in 914mm Side wall termination of less than 12 in 305mm above highest snow level Maintain 12 in 305mm min Clear ance above highest anticipated snow level or grade whichever is greater Typ Concentric Vent and Combustion Air Side Termination Roof Termination Preferred Note A denotes 0 To 2 in 51mm Between the first 2 vents T...

Страница 40: ...om Table 15 Figure 48 Combustion Air and Vent Pipe Diameter Transition Location and Elbow Configuration A93034 FURNACE NOT IN HORIZONTAL SECTION PIPE DIAMENTER TRANSITION IN SECTION NOTICE Optional Configuration for Combustion Air Inlet Pipe In applications where there is a risk of excessive moisture entering the combustion air inlet pipe a moisture trap may be added to the inlet pipe to help prev...

Страница 41: ...nt systems Use 3 Vent Tables for 80mm o d vent systems Use 4 Vent Tables for 100mm o d vent systems The measured length of pipe used in a 2 pipe termination is included in the total vent length Include deductions from the Maximum Equivalent Vent Length MEVL contained in the Venting Tables for elbows and flexible vent pipe Factory accessory concentric vent terminations or pipe lengths and elbows us...

Страница 42: ...posed pipe length s 4 When combustion air inlet piping is installed above a suspended ceiling the pipe MUST be insulated with moisture resistant insulation such as Armaflex or other equivalent type of insulation 5 Insulate combustion air inlet piping when run in warm humid spaces 6 Install the insulation per the insulation manufacturer s installation instructions NOTE Pipe length ft M specified fo...

Страница 43: ...drawing only some models may vary in appearance UPFLOW VERTICAL VENT CONFIGURATION See NOTES following figures Figure 52 Downflow Configurations A11311 Representative drawing only some models may vary in appearance DOWNFLOW LEFT VENT CONFIGURATION A11312 Representative drawing only some models may vary in appearance DOWNFLOW RIGHT VENT CONFIGURATION L11F063 Representative drawing only some models ...

Страница 44: ...ance HORIZONTAL LEFT RIGHT VENT CONFIGURATION Requires accessory Internal Vent Kit Representative drawing only some models may vary in appearance See NOTES following figures Figure 54 Horizontal Right Configurations HORIZONTAL RIGHT VERTICAL VENT CONFIGURATION Representative drawing only some models may vary in appearance HORIZONTAL RIGHT LEFT VENT CONFIGURATION Representative drawing only some mo...

Страница 45: ...p around the outlet of the vent elbow Torque the clamp to 15 lb in NOTICE The following instructions are for PVC ABS DWV vent piping only DO NOT USE THESE TECHNIQUES FOR POLYPROPYLENE VENT PIPING SYSTEMS See the polypropylene vent system manufacturer s instructions for installing polypropylene venting systems Install the remaining vent and combustion air pipes as shown below It is recommended that...

Страница 46: ...ustion air pipe adapter 14 Complete the vent and combustion air pipe as shown in Install the Vent and Combustion Air Pipe NOTICE For Polypropylene Venting Systems When using polypropylene venting systems all venting ma terials used including the vent terminations must be from the same manufacturer Figure 55 Combustion Air Pipe A13406 12 256mm minimum to 60 1524 mm or 1 additional elbow maximum CAS...

Страница 47: ... wall as shown in Figure 46 5 Disassemble loose pipe fittings Clean and cement using same procedures as used for system piping DO NOT CEMENT POLYPROPYLENE FITTINGS Direct Vent 2 Pipe Termination NOTE Follow the instructions of the vent terminal manufacturer These instructions are provided as a reference only NOTICE Recommended Support for Vent Terminations It is recommended that side wall vent ter...

Страница 48: ...rawl Space Vent Termination 3 76 mm 12 305 mm Pipe hangar VentilatedCombustion Air intake termination in crawl space Ventilated Combustion Air intake pipe CRAWL SPACE Figure 57 Attic Vent Termination ATTIC 12 305 mm min above higest level of insulation Vent through roof flashing Ventilated Combustion Air intake pipe L11F016 ...

Страница 49: ...y 12 in 305 mm Permitted only if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor See Note 4 Manufacturer s Recommendation See Notes 3 8 M Clearance to each side of the centerline extended above or below vent terminal of the furnace to a dryer or water heater vent or other appliance s vent intake or exhaust 12 in 305 mm 12 in 305 mm N Furnace combustion air i...

Страница 50: ...rance under a veranda porch deck or balcony 12 in 305 mm Permitted only if veranda porch deck or balcony is fully open on a minimum of two sides beneath the floor See Note 4 Manufacturer s Recommendation See Notes 3 8 M Clearance to each side of the centerline extended above or below vent terminal of the furnace to a dryer or water heater vent or other appliance s direct vent intake or exhaust 12 ...

Страница 51: ... notes at end of Venting Tables See Table 16 for altitudes over 4500 ft 1370m Table 15 DEDUCTIONS FROM MAXIMUM EQUIVALENT VENT LENGTH Feet Meters Pipe Diameter in 1 1 2 2 2 1 2 3 4 Mitered 90º Elbow 8 2 4 8 2 4 8 2 4 8 2 4 8 2 4 Medium Radius 90º Elbow 5 1 5 5 1 5 5 1 5 5 1 5 5 1 5 Long Radius 90º Elbow 3 0 9 3 0 9 3 0 9 3 0 9 3 0 9 Mitered 45º Elbow 4 1 2 4 1 2 4 1 2 4 1 2 4 1 2 Medium Radius 45º...

Страница 52: ...cludes FOR EACH PIPE 100 feet 30 M of vent pipe 95 feet 28 M of combustion air inlet pipe 3 90º long radius elbows and a polypropylene concentric vent kit Also includes 20 feet 6 1 M of flexible polypropylene vent pipe included within the 100 feet 30 M of vent pipe Assume that one meter of flexible 60mm or 80mm polypropylene pipe equals 1 8 meters of PVC ABS pipe VERIFY FROM VENT MANUFACTURER S IN...

Страница 53: ... 1 163 49 7 181 55 2 NA 80 000 18 5 5 66 20 1 120 36 6 159 48 5 170 51 8 100 000 NA 29 8 8 73 22 3 167 50 9 182 55 5 120 000 NA NA NA 62 18 9 175 53 3 8001 to 9000 2438 to 2743 60 000 30 9 1 82 25 0 152 46 3 168 51 2 NA 80 000 17 5 2 62 18 9 111 33 8 148 45 1 156 47 5 100 000 NA 27 8 2 67 20 4 157 47 9 170 51 8 120 000 NA NA NA 56 17 1 164 50 0 9001 to 10 000 2743 to 3048 60 000 27 8 2 76 23 2 142...

Страница 54: ...11 3 8 5 6 7 4 0 N A 80 000 20 10 Ft 35 0 39 0 39 0 33 0 25 0 35 0 118 0 107 0 92 0 76 0 35 0 130 0 125 0 109 0 90 0 M 10 7 11 9 11 9 10 1 7 6 10 7 36 0 32 6 28 0 23 2 10 7 39 6 38 1 33 2 27 4 0 20 Ft 22 0 16 0 14 0 7 0 0 0 35 0 69 0 60 0 49 0 35 0 35 0 83 0 72 0 60 0 45 0 M 6 7 4 9 4 3 2 1 0 0 10 7 21 0 18 3 14 9 10 7 10 7 25 3 21 9 18 3 13 7 20 30 Ft 11 0 5 0 2 0 0 0 0 0 35 0 46 0 39 0 29 0 16 0...

Отзывы: