INSTALLATION INSTRUCTIONS
Gas Furnace: (F/G)9MAE
440 01 4300 02
13
Specifications subject to change without notice.
Figure 9
Unconverted Factory Configuration as viewed in the Horizontal Left Orientation
Representative drawing only, some models may vary in appearance.
If alternate vent position
is required, loosen clamp
on vent elbow inlet.
Remove trap from
collector box.
Remove pressure switch tube
from port on collector box.
Remove relief tube
from relief port on
condensate trap.
Remove middle and right
plug from collector box.
DO NOT DISCARD
Remove relief tube
from port on collector
box.
A11586A
Figure 9
−
continued Horizontal Left Trap Configuration
A11586B
Representative drawing only, some models may vary in appearance.
Rotate elbow to
desired position and
torque clamp on inlet
15 lb.
−
in.
Slide relief tube in
stand
−
offs to adjust
length.
Attach condensate
trap to collector box
with screw.
Align trap over middle
and right
−
hand port on
collector box.
Install plugs in open
ports on collector box.
Connect relief tube to
port on collector box.
Trim excess tube.
Route pressure switch tube
underneath relief tube and
connect to port on collector box.
Connect relief tube to
relief port on condensate
trap.