INSTALLATION INSTRUCTIONS
Gas Furnace: (F/G)9MAE
440 01 4300 02
53
Specifications subject to change without notice.
Table 16
MAXIMUM EQUIVALENT VENT LENGTH
- Feet (Meters)
Note:
Maximum Equivalent Vent Length (MEVL) does NOT include elbows or terminations.
Use DEDUCTIONS FROM MEVL
−
Table 15
to determine allowable vent length for each application.
Note:
Vent sizing for Canadian installations over 4500 ft. (1370 M) above sea level are subject to acceptance
by the local authorities having jurisdiction.
Altitude
FT (M)
Unit Size
DIRECT VENT (2-PIPE) AND VENTILATED COMBUSTION AIR
Vent Pipe Diameter
1-1/2
2
2-1/2
3
4
4501 to 5000
(1370 to 1524)
60,000
35
(10.7)
111
(33.8)
198
(60.4)
221
(67.4)
NA
80,000
23
(7.0)
85
(25.9)
146
(44.5)
195
(59.4)
216
(65.8)
100,000
NA
40
(12.2)
91
(27.7)
200
(61.0)
222
(67.7)
120,000
NA
NA
NA
80
(24.4)
211
(64.3)
5001 to 6000
(1524 to 1829)
60,000
37
(11.3)
103
(31.4)
186
(56.7)
207
(63.1)
NA
80,000
22
(6.7)
76
(23.2)
137
(41.8)
183
(55.8)
200
(61.0)
100,000
NA
33
(10.1)
85
(25.9)
188
(57.3)
208
(63.4)
120,000
NA
NA
NA
74
(22.6)
199
(60.7)
6001 to 7000
(1829 to 2134)
60,000
35
(10.7)
96
(29.3)
174
(53.0)
194
(59.1)
NA
80,000
20
(6.1)
71
(21.6)
120
(36.6)
171
(52.1)
185
(56.4)
100,000
NA
31
(9.4)
79
(24.1)
178
(54.3)
195
(59.4)
120,000
NA
NA
NA
68
(20.7)
187
(57.0)
7001 to 8000
(2134 to 2438)
60,000
32
(9.8)
89
(27.1)
163
(49.7)
181
(55.2)
NA
80,000
18
(5.5)
66
(20.1)
120
(36.6)
159
(48.5)
170
(51.8)
100,000
NA
29
(8.8)
73
(22.3)
167
(50.9)
182
(55.5)
120,000
NA
NA
NA
62
(18.9)
175
(53.3)
8001 to 9000
(2438 to 2743)
60,000
30
(9.1)
82
(25.0)
152
(46.3)
168
(51.2)
NA
80,000
17
(5.2)
62
(18.9)
111
(33.8)
148
(45.1)
156
(47.5)
100,000
NA
27
(8.2)
67
(20.4)
157
(47.9)
170
(51.8)
120,000
NA
NA
NA
56
(17.1)
164
(50.0)
9001 to 10,000
(2743 to 3048)
60,000
27
(8.2)
76
(23.2)
142
(43.3)
156
(47.5)
NA
80,000
15
(4.6)
57
(17.4)
103
(31.4)
137
(41.8)
142
(43.3)
100,000
NA
24
(7.3)
62
(18.9)
147
(44.8)
157
(47.9)
120,000
NA
NA
NA
51
(15.5)
153
(46.6)
NOTES:
1. Use only the vent pipe sizes shown for each furnace. It is NOT necessary to choose the smallest diameter pipe possible for
venting.
2. NA = Not allowed. Pressure switch will not close, or flame disturbance may result .
3. Vent sizing for Canadian installations over 4500 ft. (1370 m) above sea level are subject to acceptance by local authorities
having jurisdiction.
4. Size both the combustion air and vent pipe independently, then use the larger size for both pipes.
5. Assume two 45
°
degree elbows equal one 90
°
degree elbow. Wide radius elbows are desirable and may be required in some
cases.
6. Elbow and pipe sections within the furnace casing and at the vent termination should not be included in vent length or elbow
count.
7. The minimum pipe length is 5 (1.5) linear feet (meters) for all applications.
8. Use 3
−
in (76 mm) diameter vent termination kit for installations requiring a 4
−
in (102 mm) diameter pipe.