2.8 Trace
The TRACE menu allows adjusting the swept spectrum curve by selecting the most suitable DETECTOR and trace type.
The DETECTOR determines which of the detected input power levels are displayed on the screen since the Airscout
Spectrum does several measurements of the same frequency range during each sweep.
The available detectors are:
• DETECTOR: AVG
Displays the averaged value over the values detected (the default detector).
• DETECTOR: MAX
Displays the highest detected input power level values.
• DETECTOR: MIN
Displays the lowest detected input power level values.
For most accurate power measurements AVG detector is recommended. If utilizing the MAX or MIN
detector, please note that a narrower VBW must be used (see
RBW & VBW
). In case the manually
selected VBW is too wide for the current RBW, there is a warning displayed on the screen, VBW
indication under the graph is
red
and the indication “UNCAL” is put under the battery symbol.
The currently used detector is indicated in
yellow
under the graph.
Entering the TRACE menu
The TRACE menu