Recording a Personal Identification Message

 

When the monitor calls out, it will first play the recorded personal 
identification message.  The message can be up to 10 seconds in 
length. 
1 From the Program Menu, press 

6

 

2 If this is the first time recording a message, you will not hear 

anything.  Go to step 4 

3 You will hear the recorded message 
4 You will hear “

Press one to change”

 

5 Press 

1

 if you wish to make a change or press any other

 

button 

to return to the Program Menu 

6 If you press 

1

 you will hear a tone 

7 Begin speaking after the tone.  The Temperature Guard will re-

cord for up to 10 seconds. 

8 After you are done recording, press any key to mark the end of 

your message. 

9 You will hear the message you recorded. 
10 You will be automatically returned to the Program Menu 

 

Programming Your PIN Number 

The monitor has a programmable 4-digit PIN number (0000-9999) 
to access the program menu, and to stop the monitor from making 
emergency phone calls.  The PIN number must be 4 digits and 
must not include a # sign. 
 

My PIN Number is 

_____________ 

 

1 From the Program Menu, press 

8

 to change the PIN number 

2 You will hear the PIN number (factory default is 0000) 
3 You will hear “

Press one to change.”

 

4 Press 

if you wish to make a change or press any other button

 

to return to the Program Menu 

5 You will hear “

Enter number”

 

6 Enter a four digit number (do not put a # anywhere in your pin 

number) 

7 You will hear the PIN number you just entered 
8 You will be automatically returned to the Program Menu 

Enable / Disable the Temperature and Power Status Message 

From the factory, the monitor prompts the caller for the PIN num-
ber before allowing the caller to hear the current temperature and 
power status.  This prevents anyone from learning that the home is 
unoccupied.  To have the monitor report the temperature and 

Содержание VM500-2

Страница 1: ...Temperature Guard Models VM500 3 VM500 3HT Home Guard Model VM500 2 Operating Manual and Installation Instructions...

Страница 2: ...Telephone Numbers 7 Programming the Number of Rings 8 Recording the Personal Identification Message 9 Programming the PIN 9 Where to locate the Monitor 10 What happens when the Monitor calls 11 Calli...

Страница 3: ...where the Tempera ture Guard is located The Temperature Guard will pick up after the first ring 3 The Temperature Guard prompts for the 4 digit PIN number Enter the factory default PIN number 0000 4 Y...

Страница 4: ...You will hear Press 1 for temperature or 2 for humidity 3 Press 2 for humidity 4 You will hear the current low limit i e Lower limit is 0 5 You will hear Press 1 to change 6 Press 1 to make a change o...

Страница 5: ...the key 4 You will hear star and then the telephone number you just en tered 5 You will be automatically returned to the Program Menu Programming a Local Identification Number For Pagers The local ide...

Страница 6: ...line plug in the power pack to an outlet and connect the power jack Use of a phone and power line surge suppressor is strongly recommended Turn the unit on by moving the power switch from the positio...

Страница 7: ...ird number Temperature Guard only or 4 for the fourth number Temperature Guard only 2 You will hear Enter number then press pound 3 Enter the full phone number 1 area code if necessary fol lowed by th...

Страница 8: ...g a delay to access outside phone line If an extra time delay between digits of a phone number is required enter to provide a two second delay For example If a 9 were required to connect with an outsi...

Страница 9: ...er The monitor has a programmable 4 digit PIN number 0000 9999 to access the program menu and to stop the monitor from making emergency phone calls The PIN number must be 4 digits and must not include...

Страница 10: ...hear the new setting C on 6 You will be automatically returned to the Program Menu Where to Locate the Monitor The monitor measures temperature and power wherever it is located If the monitor is being...

Страница 11: ...power off Example if you saw 12340751 on the pager s display 1234 is the user ID 075 indicates a temperature of 75 degrees and the last 1 indicates power is on The Temperature Guard will continue to c...

Страница 12: ...ang up Wait 30 seconds and call again After two rings the monitor will answer Verifying that the Monitor will call all the phone numbers To verify that the monitor will call all of the programmed phon...

Страница 13: ...Helpful TIPS If the Temperature Guard is having trouble receiving your pro gramming entries try holding the button for a longer amount of time Include all necessary digits for phone numbers Long dista...

Страница 14: ...etwork the telephone company will notify you in advance that temporary dis continuance of service may be required But if advance notice isn t practical the telephone company will notify the customer a...

Страница 15: ...ation and someone verifying the proper response This warranty shall terminate and be of no further effect at the time the Product is 1 damaged by extraneous causes such as fire water lightning etc or...

Страница 16: ...REV 52315 Temperature Guard A division of Microtechnologies Incorporated 564 Berlin Turnpike Berlin CT 06037...

Отзывы: