14
www.grupotemper.com
KDP21-PLUS
CONNECTION:
Warning. Danger of death through electric shock!
�
-Must be installed by professional electrician.
-
Disconnect power source.
-
Cover or shied any adjacent live components.
-
Ensure device cannot be switched on.
-
Check power supply is disconnected.
--Unload the transparent vinyl cover which is at the bottom of the sensor.
-
Loose the screws in the connection terminal, and then connect the power to connection
terminal of sensor according to connection-wire diagram.
-
Install back the transparent vinyl cover into the original location.
-
Fold the metal spring of the sensor upwards, until they are in “I” position with sensor,
and then put the sensor into the hole or installation box which is on the ceiling and has
the similar size with the sensor. Releasing the spring, the sensor will be set in this
installation position.
-
After finishing installing, turn on the power and then test it.
CONNECTION-WIRE DIAGRAM
(See the right figure)
TEST :
-
Turn the TIME knob anti-clockwise on the
minimum (10s).Turn the LUX knob clockwise
on the maximum (sun).
Infrared Motion Sensor
STEP 1 STEP 2 STEP 3