KDP21-PLUS
Infrared Motion Sensor
15
www.grupotemper.com
--Switch on the power; the sensor and its connected lamp will have no signal at the
beginning. After Warm-up 30sec, the sensor can start work .If the sensor receives the
induction signal, the lamp will turn on. While there is no another induction signal any
more, the load should stop working within 10sec±3sec and the lamp would turn off.
--
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than
3LUX, the sensor would not work and the lamp stop working too. If the ambient light is
less than 3LUX (darkness), the sensor would work. Under no induction signal condition,
the sensor should stop working within 10sec±3sec.
SOME PROBLEM AND SOLVED WAY:
--
The load does not work:
a. Please check if the connection of power source and load is correct.
b. Please check if the load is good.
c. Please check if the settings of working light correspond to ambient light.
--
The sensitivity is poor:
a. Please check if there is any hindrance in front of the detector to affect it to
receive the signals.
b. Please check if the ambient temperature is too high.
c. Please check if the induction signal source is in the detection field.
d. Please check if the installation height corresponds to the height required in
the instruction.
e. Please check if the moving orientation is correct.
--
The sensor can not shut off the load automatically:
a. Please check if there is continual signal in the detection field.
b. Please check if the time delay is set to the maximum position
c. Please check if the power corresponds to the instruction.
Note: when testing in daylight, please turn LUX knob to (SUN) position, otherwise
the sensor lamp could not work!