78
Data output
Eco/Green Driving functionality generates events on three cases. If vehicles:
Acceleration exceeds defined parameter value
Deceleration (braking) exceeds defined value
Cornering force exceeds defined value
Program continuously monitors and process data from accelerometer then decides
whether harsh event is detected or not. If any of three cases are satisfied event is
generated. Record is saved and sent to server (FM5500 must be configured properly).
Event value is multiplied by 10 before sending/saving record to get more precision
when displaying
data
*.
Digital output No.1 is activated for a period of time to warn driver. Output on-time
should/can be configured separately for each case.
*Example.
If acceleration harsh event of 3.55 m/s2 detected. Record with value 3.55*10 = 35.5
≈ 36 will be saved ant sent to server.
12.2
Overspeeding Scenario
Overspeeding.
Helps to prevent from exceeding fixed speed and inspects driver if needed.
DOUT1 is controlled by scenario for user needs, to manage buzzer, LED etc.
Mounting Requirements and Working Conditions
1.
Only one scenario on corresponding Digital Output can be enabled at once.
2.
Scenarios on Digital Output No.1 and Digital Output No.2 can be used
simultaneously.
3.
Device module mounting position doesn’t have any influence for correct scenario
operation.
Configuration
Figure 68 Overspeeding configuration parameters
Overspeeding.
Enable/Disable Overspeeding.
Max Allowed Speed.
Set speed limit to reach without triggering Overspeeding event.
longer than 0.5 second so Eco/Green Driving functionality can detect acceleration. If acceleration
lasts 1.2 seconds two harsh acceleration events will be detected and generated.
Содержание FM5500
Страница 25: ...25 Figure 16 FM5500 firmware updater screen...
Страница 67: ...67 Figure 53 Unknown Operator List...
Страница 155: ...155 24 2016 08 22 2 08 Corrected Virtual COM Port driver download link...