101
o
Hysteresis – record is generated when increasing parameter value becomes higher
than High value, and decreasing becomes less than Low value
o
Event on exit – record is generated when parameter value becomes higher than
High value or lower than Low value;
o
Event on entrance – record is generated when parameter value becomes between
High and Low values;
o
Event on both – record is generated when parameter value crosses High or Low
values;
Low – allows to choose low value for Data acquisition;
High – allows to choose High level for Data acquisition;
Figure 82 CAN data table
CAN monitoring
To start CAN bus monitoring mark Monitoring check box. Table of available CAN messages will
appear (Fig. 60). Data from CAN bus will be updated every 3 seconds. In order to see only desired
data open “Monitoring filters” menu (Figure 83).