LV-CAN200/ALL-CAN300 Technical characteristics:
PARAMETER
VALUE
Supply voltage
9 to 50V
Power supply current
Average 10mA
Max (peak) 100mA
Working temperature
-40..85 °C
Max working humidity 60 % (non condensate)
9.2
LV-CAN200/ALL-CAN300 program number selection
LV-CAN200/ALL-CAN300 must be set to program number which depends on vehicle
model.
Correct program number is always written on LV-CAN200/ALL-CAN300 mounting scheme
.
Please contact Your Teltonika sales manager to get latest supported vehicle list and
mounting scheme for your vehicle, please provide CAR manufacturer, model and year
information.
9.2.1
LV-CAN200/ALL-CAN300 program number configuration via SMS command
LV-CAN200/ALL-CAN300 program number can be set remotely, using SMS command:
lvcansetprog X
X is new program number value.
9.2.2
Selecting LV-CAN200/ALL-CAN300 program number manually
Steps to set program number:
•
Hold SWITCH down till LED stars blinking
•
Release the SWITCH
•
Then LED starts blinking and counting first digit of program number, (one blink
means digit 1, two blink digit 2 etc.)
•
To stop counter push SWITCH
•
Release the SWITCH, then LED starts blinking and counting second digit of program
number
•
To stop counter push SWITCH
•
Release the SWITCH, then LED starts blinking and counting third digit on program
number
•
To stop counter push SWITCH
•
Release SWITCH, if programming is succeded LED will blink 10 times