50
I/O events
FM3622 sends SMS event message when a configured I/O property enters and/or exits its
configured High/Low boundaries or Hysteresis event generation is chosen (Monitoring does not
generate event, so SMS event could not be configured). Every IO element SMS event can be
configured to send individual message to different numbers.
Figure 46. I/O event configuration
Figure 47. I/O SMS event configuration
5.15
I/O settings
When no I/O element is enabled, AVL packet comes with GNSS information only. After
enabling I/O element(s) AVL packet along with GNSS information contains current value(s) of
enabled I/O element.
Permanent I/O elements
(are always sent to server if enabled)
Nr.
Property Name
Description
00
Digital Input Status 1
Logic: 0 / 1
01
Digital Input Status 2
Logic: 0 / 1
02
Digital Input Status 3
Logic: 0 / 1
03
Digital Input Status 4
Logic: 0 / 1
04
Analog Input 1
Voltage: mV, 0 – 30 V
05
Digital Output 1
Logic: 0 / 1
06
Digital Output 2
Logic: 0 / 1
07
GNSS PDOP
Probability * 10; 0-500
08
GNSS HDOP
Probability * 10; 0-500
Downloaded from