64
8.2
System parameters
8.2.1
Sleep Mode (ID=1000)
Device has two sleep modes: sleep and deep sleep mode. While sleep is disabled (value 0)
module will never enter sleep mode, in sleep mode (value 1) module reduces level of power
usage by turning GNSS module to sleep, in deep sleep mode (value 2) module turns GNSS
module to sleep and switch GSM module off (note, that FM3622 do not receive SMS while in
deep sleep).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
8.2.2
Sleep timeout (ID=200)
Sleep timeout is time after which FM3622 goes to sleep or deep sleep if other
requirements are met. It is measured in minutes.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
1
3000
-
U8
8.2.3
Analog Input value range (ID=1001)
Analog input measuring resolution and range can be defined as 0…10V (value 0) or 1…30V
(value 1).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
U8
8.2.4
Stop Detection Source (ID=1002)
Device can operate and change its working mode according to motion detection source:
ignition (value 0), movement sensor (value 1), GPS (value 2).
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
U8
8.2.5
Static Navigation (ID=1003)
When static navigation is enabled, FM3622 filters out GPS jumps, when it is not moving.
When it is disabled, it does not make any changes to collected GPS data.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
1
U8
Downloaded from
www.Manualslib.com
manuals search engine