71
8.6.9
Trip Continuous distance counting (ID=1283)
For this feature I/O#11 ODOMETER must be enabled. If I/O ODOMETER is enabled, and
Continuous distance counting variable is set to Continuous (value 1), TRIP distance is going to be
counted continuously (from TRIP start to TRIP stop) and shown as I/O ODOMETER value.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
I/O#11 – Odometer (ID = 1410-
1415)
U8
8.6.10
Geofencing
In this chapter it is explained how to get all parameters for the first Geofence zone (all ID
numbers are for the 1
st
zone). And at the end of the chapter (part 8.6.10) is presented a table
with the IDs of all the rest Geofence zones.
8.6.10.1
Frame border (ID=1020)
Geofence border thickness, measured in meters.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1000000
1000
All Geofencing parameters
U32
8.6.10.2
Geofence Zone #1 Shape (ID=1030)
Geofence shape parameter can be: circle – value 0; rectangle – value 1.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
1
-
All Geofencing parameters
U8
8.6.10.3
Geofence Zone #1 Priority (ID=1031)
Parameter defines Geofence priority: 0 is low, 1 – high, 2 – panic;
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2
-
All Geofencing parameters
U8
8.6.10.4
Geofence Zone #1 Generate Event (ID=1032)
Generate event on:
a) No event – value 0
b) On entering zone – value 1;
c) On exiting zone – value 2;
d) On both – value 3;
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
3
-
All Geofencing parameters
U8